18 — CX9/A702 Remote Weighing Platform
18–7
CX20/CX30/CX34 Service Manual
6
Locate the bottom arm of the 15221 in the forward slot with top arm in
the locating pin as shown in Figure 18.3.
7
Hold the bottom arm firmly and pull the top arm until the cross assembly
is in position. Replace the two retainers.
8
Replace the top housing and secure to the base with the four
instrument head screws.
9
Locate the weighplate in its correct position.
10
Carry out the configuration and calibration routines as detailed in
Sections 6 and 7.
Figure 18.5
Fitting the transducer using a 15221