5 — Setting Up Procedures
5–10
CX20/CX30/CX34 Service Manual
5.7
Test Weight (Menu Option)
To check the calibration of the machine by using a known weight carry out the
following procedure:
What You Do
What You See
1
Enter service mode (see Section 5.2).
CONFIGURATION
2
Move to the TEST WEIGHT menu.
TEST WEIGHT
3
Press ENTER.
3
TEST MODE
0 : 0
4
Place test weight of known value on
weighplate (for example: 5 kg). Check
reading in weight display.
5
TEST MODE
5 : 0
5
Remove weight.
6
TEST MODE
0 : 0
6
Press SHIFT then ENTER.
TEST WEIGHT
If weight display reading does not correspond to known weight, re–calibrate the
machine (refer to Section 7).