23 — RS232 Interface PCB (CX20 W)
23–6
CX20/CX30/CX34 Service Manual
23.2.8
ULMA 200 series wrapper protocol
The ULMA 200 Series machine enables a remote device to select any of 99
preset wrapper programs via a program reference number transmitted serially.
The program number has film dimensions and tension parameters stored in the
wrapper.
As the ULMA RS232 channel is receive only the scale has to transmit a small
range of ASCII control strings:
String ’S’ starts a wrapper cycle.
String ’P, Digit low, Digit high’ selects a wrapper program (for example,
’P, 1, 4’ selects program number 41).