Page 1: ...TEC Electronic Computing Scale SL 9000 LSB SERIES Owner s Manual...

Page 2: ......

Page 3: ...cation Prohibited Do not plug in or unplug the power cord plug with wet hands as this may cause electric shock Do not place metal objects or water filled containers such as flower vases flower pots or...

Page 4: ...ting normal operations When moving the machine take hold of the case and lift the machine Never hold the remote unit Do not place the machines on unstable or slanted surfaces as they may drop or fall...

Page 5: ......

Page 6: ...REMOVAL AND REPLACEMENT OF MEDIA 9 1 10 OUTLINE OF OPERATION 10 1 11 PROGRAMMING PROCEDURES 11 1 11 1 UNIT PRICE CHANGE 11 4 11 2 PLU DATA SETTING 11 5 11 3 INGREDIENT MESSAGE 11 7 11 4 NUTRITION FAC...

Page 7: ...OUNT OPERATION 14 4 14 4 PRINT COUNT OPERATION 14 6 14 5 ISSUING LABELS WITH NET WEIGHT STATEMENT FOR US TYPE ONLY 14 9 14 6 TARE SAVE FUNCTION PROCEDURES 14 11 14 7 CALLING AND PRINTING GRADE LINES 1...

Page 8: ...und to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipme...

Page 9: ...play Type LS Liquid Crystal Display and 7 segment Display Max Capacity 30M 30 lbs decimal pound multi interval 15M 15Kg multi interval 1 2 ACCESSORIES Owner s Manual EM1 31071 Remote Display Speed Key...

Page 10: ...quid Crystal Display 5x7 dots 16 characters 1 line LCD Weight 5 digits US CA type 5 digits QR AU type Unit Price 4 digits US CA type 5 digits QR AU type Total Price 5 digits US CA type 6 digits QR AU...

Page 11: ...EMO PC Board Memory Module Label Cassette Description Source Model No or Part No A modular connector used to connect scales to each other in a LON configuration A modular resistor attached to the scal...

Page 12: ...sed Remote Display Meat Platter Right Cover Adjustable Legs RS 232 I F MALE Option TMCC I F MALE Option RS 232 I F FEMALE Option Level Gauge Liquid Crystal Display Print Head Operation Keyboard Speed...

Page 13: ...it to the remote display Refer to Section 7 How to affix the remote display sheet CA CANADA SL 9000 WEIGHT POIDS ZERO T NET kg lb ZERO REG M D R W 100g PREPACK PRE EMBALLE ERREUR X Z LON INLINE ERROR...

Page 14: ...LINEA ERROR PRECIO TOTAL PRECIO UNITARIO kg WEIGHT kg UNIT PRICE kg ZERO NET REG M D R W 100g FIX X Z LON INLINE ERROR TOTAL PRICE WEIGHT kg UNIT PRICE Rp kg ZERO NET REG M D R W 100g FIX X Z LON INL...

Page 15: ...DISPLAY 4 4 AU TYPE 4 4 AU TYPE SL 9000 CERO NET REG M D R W 100g FIX X Z LON INLINE ERROR WEIGHT kg UNIT PRICE kg TOTAL PRICE WEIGHT 0 6 Kg 6 15 Kg e d 0 002 Kg 0 005 Kg Max 15 Kg Min 0 04 Kg TARE T...

Page 16: ...Programming Keyboard Function Function 1 Clears preceding numeric data 2 Releases the scale from the error mode Toggles between the upper characters or lower characters Calls the next PLU data item S...

Page 17: ...scriptors Stores Ingredient data in the temporaty memory Calls ingredient data from the temporaty memory Sets the preceding item when setting PLU and nutrition information Sets the following item when...

Page 18: ...54 63 PRESET COUNT GRADE LINE LOGO ST FEED ESC NEXT PLU PROG VOID POWER SAVE FOR DT TM 7 8 9 4 5 6 1 2 3 0 PLU PRT T C TEST ZERO GROUP 3 1 1 2 2 US type 1 2 1 4 CA QR AU type 100 g LB kg 1 2 Primary f...

Page 19: ...he other 70 speed keys 2 Selects the function for change Print OFF 3 Selects a menu group Returns to the main menu Accesses print item auto message timer print format and issue mode selection mode Tur...

Page 20: ...Optional key by initial setting Feeds the label Issues a test label Adjusts the zero point Changes the label issue mode between Automatic issue and manual issue Optional key by initial setting Calls...

Page 21: ...PC AT keyboard if necessary 8 Turn the power on and then press the power key See page10 1 9 Set the following program menus 6 PROCEDURE BEFORE OPERATION Menu Group ITEM No Programming Name 2 0 PRINT F...

Page 22: ...connector cover and install the remote blind plate Then tighten the screws to secure the remote display 3 Remove the tape from the remote packing and remote cap and lower to fit them to the scale 7 I...

Page 23: ...affixing the sheet or sticker CA Type Affix the remote display sheets to the depressed area of the remote display on both sides Operator side and customer side QR Type Affix the remote display sticker...

Page 24: ...ale by turning the adjustable legs so that the air bubble is inside the center circle 8 LEVEL ADJUSTMENT 2 Adjustment Procedure When the air bubble moves toward the left side turn the right adjustable...

Page 25: ...edia core with backing paper Label Cassette Roll Stopper Backing Paper Stopper Backing Paper NOTE When removing the backing paper loosen the paper by turning the paper winding shaft counterclockwise W...

Page 26: ...in the SL 9000 may cause a label skew NOTE Ensure that the label guide plate aligns with the dowel 6 Refer to the figure below and set the media on the label cassette 7 Insert the roll stopper into t...

Page 27: ...y OFF Press the POWER key Password Input REG Menu Refer to Section 14 or Increment Other than Menu 1 Unnecessary Menu 1 Necessary Press Press No Press No Press Menu No 1 REWRAP Menu Refer to Section 1...

Page 28: ...enter the password 2 In Sections 11 1 11 2 and 11 3 items which have been sold on that day cannot be called unless they are reset or the Initial Setting 1 4 is set to 1 How to Select Menu and Item No...

Page 29: ...PLU 11 12 6 ADDRESS SETTING 1 5 PROGRAM ADDRESS 11 13 7 SPECIAL INFO 1 7 PROGRAM SPECIAL INFORMATION 11 14 8 GRADE LINE 1 8 PROGRAM GRADE LINE 11 14 9 SPEED KEY SETTING 1 9 ASSIGN COMMON PLU TO SPECIF...

Page 30: ...space to be inserted and press INSERT key 3 To delete a line press DELETE B key 4 To move the cursor to the preceding line press key or key when entering a commodity name 5 Pressing the key toggles be...

Page 31: ...ation keys except when calling a PLU by using a speed key NEXT PLU VOID TEST PROG ESC 0 or Enter the PLU Enter the Speed key Speed key 1st half 2nd half PRT PRT MENU Group 1 MENU Group 1 Main MENU Cha...

Page 32: ...x4 lines ENTER Is status of initial set 7 8 0 or 1 2 Is status of initial set 8 1 In what mode is PLU used Is status of initial set 1 6 Enter UPC max 6 dig Is status of initial set 26 4 ENTER Enter qu...

Page 33: ...follows 1 In case of lb scale a INSERT1 key per lb b DELETE A 1 2 key per 1 2 lb c RETURN 1 4 key per 1 4 lb 2 In case of kg scale a INSERT 1 key per 100 g or Kg CA QR type only 5 Tare limit should b...

Page 34: ...2 ENTER or NEXT PLU Enter the PLU max 6 dig Enter the ingredient message Refer to Page 11 3 Pressing the key calls data stored by pressing the key Pressing the key temporarily stores data into the wo...

Page 35: ...PLU max 6 dig Enter the Servings Per Container Enter the Serving Size Enter the Calories 0 9999 ENTER ENTER Enter the Total Fat 0 99999 or 0 0 999 9 Enter the Saturated Fat 0 99999 or 0 0 999 9 Addit...

Page 36: ...tored 3 The additional information can be used only when its title has been registered in Section 11 16 Pressing the key instead of the ENTER key proceeds to the next menu Pressing the returns to the...

Page 37: ...hydrate Necessary daily intake of Dietary Fiber Percentage of necessary daily intake of Calories Percentage of necessary daily intake of Total Fat Percentage of necessary daily intake of Saturated Fat...

Page 38: ...xxxxx xxx xxxxxxxxxx xxx xxxxxxxxxx xxx xxxxxxxxxx xxx Percent Daily Values are based on a 2 000 calorie diet 1 st Address 2 nd Address Nutrition Facts Serving Size 1234567890123 Servings Per Containe...

Page 39: ...pressed 3 Pressing the CLEAR key releases the scale from the error mode and returns to the initial status of this menu 4 After clearing a paper jam error the scale will wait for an entry of PLU again...

Page 40: ...inted on label can be set within the following character limits Address 32 characters x 2 lines Receipt Header 24 characters on the 1st 2nd line and 48 characters in the 3rd line 5 0 9 MENU Group 1 PR...

Page 41: ...t weight data is printed 7 TEST ENTER ENTER PROG ESC MENU Group 1 Main MENU MENU Group 1 Enter the special information Refer to page 11 3 11 8 Grade Line Menu Group 1 Item No 8 You can set the maximum...

Page 42: ...assigned to department and the lower four digits to PLU The department is automatically added in front of four digit PLU and treated as a six digit PLU In case of PROG Report and Reset modes PLU is t...

Page 43: ...position Range 0 9 Enter the correct value for address position Range 0 15 Enter the correct value for pre feed area Range 0 65 ENTER ENTER ENTER ENTER CHANGE PLU MENU Group 2 Main MENU Select the It...

Page 44: ...rition Printing Label length mm 48 mm width 30 0 40 0 54 0 68 8 82 6 92 0 69 9 84 1 106 4 76 2 90 5 104 8 112 7 112 7 Variabe Length 57 mm width Print of the NET WT statement Impossible Possible Kind...

Page 45: ...time Hour Minute Set the machine No max 6 dig Set the store No max 5 dig PROG ESC MENU Group 2 Main MENU 11 12 CMT PL 3 Menu Group 2 Item No 2 CMT OPERATIONS SL 9000 is designed to interface with a Ca...

Page 46: ...tion ends when 00 appears in the 7 seg display and LAMP goes off Remove the data disc and turn the power off 4 Be sure to start the PL 3 before the main operation Table 3 Error code during PL 3 operat...

Page 47: ...NG 2 COMPARE PLU ING IN OLD FORMAT READ PLU ING 3 READ PLU ING IN OLD FORMAT WRITE PLU TO CMT 4 SAVE PLU IN NEW FORMAT VERIFY PLU CMT 5 COMPARE PLU IN NEW FORMAT READ PLU FM CMT 6 READ PLU IN NEW FORM...

Page 48: ...MENU The transmission delay time can be set when in line system is selected for TMCC Refer to Table 5 l l MENU Group 2 3 Select mode TMCC OFF line Set ID numbers Range 0 255 ENTER ENTER NOTES 1 The T...

Page 49: ...etting numbers other than the above results in an error NOTES 1 Before starting the above procedure press the key and enter IN LINE mode 2 When installing the backup master terminal set the master sca...

Page 50: ...p n Errorous terminal is displayed NOTE DLL is performed automatically in the following two ways It is selectable by the Initial Settings 0 6 and 0 7 1 LOCK SCALE method Step 1 LOCK SCALE is sent 1 S...

Page 51: ...ENTER ENTER 1 1 2 3 4 2 3 4 5 6 6 or NEXT PLU q q ESC PROG MENU Group 2 Main MENU Set the flag Left Right Enter a price Enter an UPC Move the cursor to the column to be set Switch over the setting it...

Page 52: ...The usable keys to set the column are as follows 11 15 BAR CODE FORMAT PLU 1 2 3 4 5 6 Display H H H H H H 1 2 3 4 5 6 FLAG 0 9 PLU 1 6 UPC 1 6 PC D 1 PRICE 1 6 WEIGHT 1 6 C D 1 4 Digits and display...

Page 53: ...ume Before starting this operation set the initial setting 7 3 to 1 MENU Group 2 ENTER ENTER 7 ESC PROG MENU Group 2 Main MENU Enter the title See NOTE Enter the title See NOTE NOTE Title No and forma...

Page 54: ...8 ESC PROG MENU Group 2 Main MENU Load the tape into the CMT Loader Select a transmission item 1 SAVE SL 9000 CMT 2 VERIFY SL 9000 CMT 3 LOAD SL 9000 CMT Table 6 Error message during data transmissio...

Page 55: ...r r PROG MENU Group 2 Main MENU Enter an idiom Max 20 charas Set an idiom 1 50 11 19 VENDOR SETTING Menu Group 3 Item No 0 Up to 40 vendors can be registered using the following procedure The vendor...

Page 56: ...dth an error will occur Key functions Moves downward Data is stored Moves downward Data is stored Moves upward Data is stored Moves to the right Moves to the left Selects a setting a ROT Rotation 0 90...

Page 57: ...0 11 13 15 16 21 23 25 26 31 33 35 and 36 3 Length 30 200 mm 4 Number of ingredient message lines 0 38 lines 5 Bar code height 0 39 mm 5 Each print item should be printed in the following range No 1 2...

Page 58: ...ses use normal labels POS Format 10 16 10 0 mm NET Format 21 26 10 0 mm Bar code Format 31 35 8 5 mm 2 Free format area A B C D A B C D A B C D A B C D When setting the print item positions X and Y an...

Page 59: ...T SELL BY WEIGHT T WEIGHT U PRICE T U PRICE PRICE T PRICE BARCODE ADDRESS TARE T TARE RELISH T RELISH S INF N WT MARK M R LOGO S HANDLING Available Not available COMMODITY NAME INGREDIENT MESSAGE PAC...

Page 60: ...is framed in black in the figure on page 5 1 but not on the programming keyboard How to access the READ menu Press the ESC key to access the following display Enter 5 and the scale will enter the REA...

Page 61: ...er from small to large All the preset grade line contents are listed All preset vendor names are listed All preset idioms are listed Report Name PLU programmed data report Commodity description report...

Page 62: ...t menus to be protected Remote display WEIGHT UNIT PRICE TOTAL PRICE 1 0 0 0 0 0 P M R S XZ 0 Protected Accessible with a password entry Unprotected Exclude menus the password A cannot access Remote d...

Page 63: ...E 1 1 1 0 1 1 P M R S XZ 0 Valid 1 Invalid Unnecessary Enter password B as 4 digits NOTES 1 Select validity of the password by pressing the key 2 When the same password is entered for password A and B...

Page 64: ...NOTE When the password is unknown enter HELP instead and you can access only security menu 13 2 CALLING MENU BY ENTERING PASSWORD Liquid Crystal Display PROG 0 REG 1 MARK DOWN 2 REWRAP 3 SECURITY 4 RE...

Page 65: ...nrated power source inaccurate scaling or other errors may occur 6 If the zero point has shifted during scaling and no tare is displayed adjust the zero point by depressing the ZERO key 7 Check the da...

Page 66: ...ay T BONE STEAK REG Remote Display NET WT SELL BY PACKED ON PRICE lb Sample label NOTES 1 Pressing a speed key to which no PLU data has been assigned will result in an error In this case press the C k...

Page 67: ...le will be printed as the Total Price regardless of its actual weight and the weight is also printed on the label Menu REG M DOWN or REWRAP Mode FIX Example In the case of PLU 636 of fixed price 3 80...

Page 68: ...DONUTS for 1 50 of price for 4 DONUTS When a price of 1 50 4 DONUTS is set for PLU 33 3 3 1 0 PLU PRT PRT Single label is issued The label is issued in succession after peeling it C C PLU Enter the PL...

Page 69: ...item can be sold as below 1 piece at 15 dollars 15 pieces at 10 dollars 15 pieces sold at 0 5 dollars per 10 pieces Enter the PLU Press Press Press Enter quantity Enter quantity Enter total price ex 3...

Page 70: ...ed with the backing paper attached When all the specified numbers of the labels are being issued C C C Remove the commodity PRT NOTES 1 A batch issue means to print labels continuously with the backin...

Page 71: ...with the backing paper attached The next label is issued after removing the current label When all the specified numbers of labels are being issued C C PRT PRT Enter the PLU Press Press to save the P...

Page 72: ...trition information labels are issued in the following methods Issue mode Weigh Fix Weight price Fix Net weight By count Manual issue On demand Pre 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Page 73: ...ht of this commodity is 19 oz and decides to sell it at 2 00 Enter the PLU 8 1 6 2 1 9 3 0 0 PLU PRT FOR PRT The label is issued The label is issued Labels of identical print data will automatically b...

Page 74: ...Unit price calculation system Step 1 Weight data is calculated from royal lb into decimal lb Round off the data to two decimal places ex 21 oz 1 3125 lb round 1 31 lb Step 2 Price is divided by the v...

Page 75: ...2 205lb for the CA QR AU type When tare subtraction is in operation however the scalable range for net weight becomes less by the amount of the tare Net weight Gross weight Tare 2 Preset tare must be...

Page 76: ...G M DOWN or REWRAP Mode WEIGH or FIX or BY COUNT WEIGHT Remote Display Liquid Crystal Display Commodity Name DONUTS UNIT PRICE TOTAL PRICE P 4 3 76 WEIGHT Remote Display Liquid Crystal Display ENTER T...

Page 77: ...G M DOWN or REWRAP Mode WEIGH FIX or BY COUNT Press LOGO 1 0 0 C PRT or Start the label issue operation Enter the logo 1 to 26 Press Clear the entered logo NOTES 1 The logo will be effective until it...

Page 78: ...Press Table 9 Darken Lighten Entry 1 2 3 4 5 6 7 8 Packed on date Print Non Print Sell by date Print Non Print Commodity name Print Non Print Weight Print Non Print Unit price Print Non Print Total p...

Page 79: ...4 Pressing the C key allows you to return to the step of selecting the packed on date 5 The range of idle time 0 to 99 seconds A setting 0 prohibits display of an auto message 6 Item 29 is operable on...

Page 80: ...COUNT 3 1 NEXT PLU NEXT PLU FOR or VOID 1 0 PRT PRT z A The label is issued Enter the PLU Press Press Enter the number of labels to be issued max 99 Register next preset item Change or cancel the numb...

Page 81: ...E PRT PRT LOGO Enter the quantity Call the Grade Line Enter the required Grade Line 1 to 49 Press Call PLU designation LOGO 1 Enter the required LOGO 1 to 26 Press 1 By calling the PLU designation LOG...

Page 82: ...selected pressing the PRESET COUNT key in FIX mode results in an error 2 Programmed items are reset when the power is off changing the menu PROG REG changing the mode weigh by count fix batch printin...

Page 83: ...en on Maximum number of registerable commodities One scale 200 commodities One vendor 99 commodities NOTE Print format varies depending on the settings of the Initial Setting 11 1 11 2 11 3 11 4 and 1...

Page 84: ...procedure Enter vendor VOID VOID NEXT PLU or PRT C Subtotal The following procedure will sum up all of the registered items Enter vendor Enter prices A receipt will be issued ST C PRT Enterthedeletion...

Page 85: ...eared after they are printed on labels or journal paper 15 TOTAL OPERATION ESC ESC 5 6 or Issue each Report No 0 1 2 3 HOURLY TOTAL GRAND TOTAL PLU TOTAL VENDOR TOTAL ITEM REPORT RESET JOURNAL LABEL H...

Page 86: ...ing paper Issued sequentially in batch mode 3 If the C key is pressed during issuance the hourly report being printed will complete then the total report will be issued If this is done in Reset mode t...

Page 87: ...ock or zone have no sales record only the total is printed 3 Pressing the C key in the middle of issuing a reset report stops printing and data is not cleared 15 4 VENDOR TOTAL REPORT PRT PRT 3 Enter...

Page 88: ...EAR key and re input the right data Press the CLEAR key and delete unnecessary PLUs Press the CLEAR key and check the PLU Press the CLEAR key and set the data to free PLU Press the CLEAR key and re in...

Page 89: ...end Label overruns Press the C key and re input the right data Press the C key and check the PLU Press the C key then the ESC key and select RESET Then sum up the exceeded memory Press the C key then...

Page 90: ...not turned OFF and ON again after setting ID Text data number is incorrect Registration job is performed on a satellite scale while reset job is per formed on the master scale The backup master does...

Page 91: ...el on the cutter wipe off paste with alcohol After removing the label cutter reattach it using the following procedure 1 Install an unloaded label cassette on the scale 2 Install the label cutter alig...

Page 92: ...windy location Avoid locations subject to the wind 1 Check that the media is loaded correctly 2 Check whether the print head is set correctly or not Dirty print head Clean the print head Call the TOSH...