70
4.6.2
Setup the IP PTZ Camera
1. In the PTZ control panel, click
Setup
.
2. When the PTZ Setup dialog box appears, click
IP PTZ
tab.
3. Select the camera number and check the
Use PTZ
box.
4. In the Connection Settings section, select the
Protocol
and
Model
of PTZ camera that user
wants to connect
and enter the IP or URL of IP camera in
IP Camera Site
column. Mark the
Authentication
box if
ID
and
Password
is required when connecting to IP PTZ camera. And
then, click
Save
to keep the settings.
5. In the
Preset Setting
section, use the PTZ control panel and adjust the position of the PTZ
camera and select the preset number to assign a number for the PTZ camera current position.
6. Set the
DwellTime
(1-60 sec) for how long the IP PTZ camera stays in that position before it
moves to the next one. If you want to add description, check the
Show Preset Name
box and
in the
Preset Name
text box, type the word. When done, click
Save
to keep the settings.
7. Repeat step 5 & 6, if you want to save another IP PTZ camera position.
i
- The numbers of preset position are depended on the IP camera protocol has
supported.
- Only Pelco-P and Pelco-D protocol can support over 16 PTZ preset points.
- Only
Canon
has supported “
Auto Pan Speed
” function.
8.
Restore AutoPan Time:
set a time period for restoring auto path function after the IP PTZ
camera has been moved. Mark the check box and set the time period in second.