Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya Communication
Manager
555-233-115
5-96
Issue 7 November 2003
4. Behind control carrier A of EPN cabinet 3:
■
Install a lightwave transceiver on cable connector at slot 3A02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■
Connect the other end of the fiber optic cable to the lightwave
transceiver, just installed, at slot 3A02. See
■
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
■
At the top of the cabinet, coil up the surplus fiber optic cable and
attach it to the wall of the cable tray.
Figure 5-15.
Standard Reliability with Two or Three Port Networks
Figure Notes
1. Cabinet 1 Processor Port Network
2. Cabinet 2 Expansion Port Network 1
3. Cabinet 3 Expansion Port