Upgrading R5si/R6si to an Avaya DEFINITY Server R
EPN running Avaya Communication Manager
555-233-115
4-52
Issue 7 November 2003
■
Two, 4, 6, or 8 pairs of wall-field cables (provided with the CSUs)
■
5, 10, or 15 dB attenuators (single-mode fiber only).
For a critical reliability system with 2 DS1 CONV-remoted EPNs, this arrangement
requires:
■
12 DS1 CONV circuit packs (TN1654)
■
12 DS1 CONV-to-EI cables (847245750 and/or 847245768)
■
12 H-600-348 cables
■
6, 12, 18, or 24 pairs of CSUs
■
6, 12, 18, or 24 pairs of wall-field cables (provided with CSUs)
■
5, 10, or 15 dB attenuators (single-mode fiber only).
For 1 or 2 Collocated Expansion Port Networks.
1.Behind port carrier C of the
multicarrier PPN. See
:
a. Install a lightwave transceiver on the connector at slot 1C02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
b. Connect 1 end of the appropriate fiber optic cable to the lightwave
transceiver just installed.
c. Route the fiber optic cable from the lightwave transceiver to the
cabinet’s cable tray and down, out of the cabinet, to the EPN stack.
d. Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
5-dB Attenuator
106060718
10-dB Attenuator
106060734
15-dB Attenuator
106061021
5-dB Attenuator
106060718
10-dB Attenuator
106060734
15-dB Attenuator
106061021