Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya Communication
Manager
555-233-115
5-84
Issue 7 November 2003
Installation (direct connection)
If you have a direct connection between the RFA and the switch:
a. Go to the RFA website, and, following the instructions in the “Deliver
to G3r/G3si/G3csi” chapter of the RFA Job Aid, deliver the License
File.
NOTE:
This procedure sends the License File to the switch and installs it.
b. If the system has IP endpoints registered, and you unplugged the
Ethernet cable from the TN799 (C-LAN) circuit pack, replug the
cable.
This re-registers the IP endpoints.
c. Continue with Step 4 below.
Installation (no direct connection)
If you do not have a direct connection between RFA and the switch:
a. Go to the RFA website, and, following the instructions in the “Deliver
to G3r/G3si/G3csi” chapter of the RFA Job Aid, deliver the License
File to your laptop/PC.
b. Open the License Installation Tool (LIT) application at your
laptop/PC.
c. Use the LIT instructions to add a switch connection profile to the
tool.
d. Use the LIT instructions to install the License File on the switch.
e. Continue with Step 4.
4. Type save translation and press
Enter
.
After the translations have been copied (about 10 minutes), the system
returns an error code, which must be a zero; otherwise, the translations are
not copied.
5. Type reset system 4 and press
Enter
.
Wait until the system has completely reset before continuing.
6. Type change cabinet 1 and press
Enter
.
In the
Carrier Type
column change the “B” carrier to processor and
submit the form.
7. Type change system-parameters duplication and press
Enter
.
Set the
Enable Operation of SPE Duplication
field to y and
submit the form.