Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya Communication
Manager
555-233-115
5-98
Issue 7 November 2003
Figure 5-18.
Collocated Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At control carrier A of PPN cabinet 1. See
■
Install a lightwave transceiver on the cable connector at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■
Connect a fiber optic cable to the transceiver just installed.
■
Route the cable to the cable tray and down, out of the cabinet,
through the cable manager to the PDS cross-connect facility.
■
Connect the fiber cable to the lightguide interconnect unit provided.
■
Carefully attach the cable (with cable ties) to the wall of the cable
tray at the built-in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
■
Install a lightwave transceiver on cable connector at slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■
Connect a fiber optic cable to the transceiver just installed.
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier A Slot 2A02
3. To EPN 1 Carrier A Slot 3A02
4. Fiber Optic Cable
5. TX Connector
6. RX Connector
cydff05 CJL 103196
RX TX
2
2
1
1