27
Assembly Instruction
FV1 / FV3 / FV4
07
e
leCtriC
ConneCtion
Direction of travel
OPEN
CLOSE
Polarity reversal
+
+
-
-
Wire colour coding
Colour
DIN IEC 757
white
WH
brown
BN
blue
BU
green
GN
violet
VT
grey
GY
Connection assignment from the locking drive
Connection assignment from the opening drive
M
Make sure when establishing the connection
that there is no voltage at the terminals!
Unused wires must be safely insulated!
I
nstallatIon
step
12:
e
Lectric
connection
BN
BN
BN
VT
WH
WH
GN
BU
BU
BU
AK
AK
Opening
drive
WH
is used for communication
in systems with synchronized
multi-drive operation.
WH
is used for commu-
nication in systems with
synchronized multi-drive
operation.
Version Z
:
contact max. 24 V, 500 mA
(min. 10mA)
In drives KS4: standard „CLOSE“
optional
„OPEN“
BN
+
-
BU
-
+
BN
+
-
BU
-
+
Multi-drive operation:
Opening drive and locking drive
Configuration with
M-COM
Opening drive is
Master / Slave
The programming of the drives in multi-drive occurs at factory or on site
with UniPC
WH
:
is used for communication, with synchronized multi-drive operation.
WH
wires connect, otherwise no function.
Optional: 1 to 4 drives and max. 2 locking drives are possible.
+
+
-
-
FV4
Junction box
site-supplied
Opening drive
Opening drive
polarity reversal
+
+
-
-
FV4
Junction box
site-supplied
Opening drive
Master
Opening drive
Slave
polarity reversal
FV4
FV1
FV3