5
Assembly Instruction
FV1 / FV3 / FV4
P
reliminary
remark
01
Hazard analysis according to DIN EN 60335-2-103
Contact-free anti-trap protection
(20.ZAA.8.1)
Passive infra-red and active light sensors
or
pressure mats
Contact-based anti-trap protection
(20.ZAA.8.2)
Pressure-sensitive safety switch strips
or
Motor current monitoring systems
(internal and external)
Hold-to-run switch:
stops movement at HSK < 20 mm
at a closing force of > 150 N at HSK
(20.ZAA.5)
Operating element in
direct range of vision:
a.) Key switch or
b.) other switch,
then: installation > 1,5 m,
inaccessible for public
(7.12.1)
Keep people away during closing!
Declaration of Conformity
power operated window
+ CE label
c
aUtion
Protection devices
c
aUtion
Use of the drive
NRWG according to
EN12101-2 without
dual purpose for ventilation
NRWG according to
EN12101-2 with
dual purpose for ventilation
(1.Z.109)
Natural ventilation
Installation height of drive and lower
edge of casement: > 2,5 m above fl oor
(ZAA.20.2)
Opening at HSK: < 200 mm and
Speed at HSK:
CLOSE
<15 mm/s /
OPEN
< 50 mm/s
(20.ZAA.2)
Yes
Yes
No
No
No
risc assessment
required
Observe danger at NSK
< 2,5 m above fl oor!
c
aUtion
Keep people away during closing!
c
aUtion
Environment with children /
vulnerable people
The information in the brackets
refer to the chapters of DIN EN 60335-2-103.
Risk analysis according to the
Machinery Directive required
Casement data
Facade:
bottom-hung
window,
top-hung-win-
dow,
side-hung
window.
Roof: roof window / sky light.
Opening direction: inward opening, outward opening.
Profile material: aluminum, steel, plastic or wood.
When inspecting the drives for conformity with on-site
requirements the following items must be observed:
• total weight of casement (glass + frame),
• casement size (FAB x FAH),
• driving force and stroke,
• mounting site at the window frame and casement
frame.