30
Assembly Instruction
FV1 / FV3 / FV4
USKM
Order number:
Application:
Rated voltage:
Close circiut current:
Connections:
Rated current per drive:
Drive type:
Protection rating:
Ambient temperature range:
Surf. mount. plastic housing:
512140
Control module with 3 outputs
and individual settuble cut-off
current, monitored motion run,
delayed sequence control.
24V DC +/- 20 %, (max. 2 Vpp)
< 50 mA
max. 3 drives; s < 300 mm
max. 2,5 A
S1, S2, S3, S12, MP, FV1, OFV1
IP 54
0 °C ... +70 °C
110 x 110 x 66 mm
Features / Equipment:
DIP switches for settings
connection terminals: 2,5 mm²
Functions:
External electronic cut-off
switch (max. 0,9 A),
motion-monitoring
up to 3 drives / locking drives,
max. 2 sequential controls
UniPC with configuration interface
Order number:
Application:
Rated voltage:
Parameterizable
drives:
Scope of delivery:
524178
Hard- and software for configuration of
drives supplied by
a
umüLLer
GmbH
24V DC +/-20%
24V DC type MP, S3, S12, S12 V.2
230V AC type S12, S12 V.2
software UniPC (Downloadlink*), Interface
“ParInt”, USB cable, connection cable
* http://www.aumueller-gmbh.de/
Downloads
Features /
Equipment:
Power supply 24V DC
is not included in the
scope of delivery!
Any extended settings
require a software
licence.
Any reconfiguration of a drive is entirely at the
user‘s own risk and responsibility.
M-COM (Main control unit)
Order number:
Application:
Rated voltage:
Current consumption:
Drive type:
Protection class:
Ambient temperature:
Dimensions:
Connecting wires:
524177
Configuration module for the automatic
configuration and monitoring of max. 4
opening / 2 locking drives type S12 / S3
in multi-drive systems.
24V DC +/- 20%, (max. 2 Vss)
<12 mA
S12
IP30 rubber jacket
0 °C ... + 70 °C
45 x 17 x 6 mm
3 wires 0,5 mm² x 50 mm
Feature / Equipment:
printed circuit board with
connecting wires for in-
tegration in site-supplied
junction box.
Cable junction box (for renewal)
Order number:
Application:
Rated voltage:
Material:
Protection class:
Dimensions:
Equipment:
513344
to extend a drive cable
only for „safety extra low voltage“
to max. 50V DC/AC
stainless steel (V2A)
IP 40
25 x 27 x 150 mm
with cable gland (grey)
including strain relief,
with 2 loose ceramic terminals
(bipolar).
ca. 1
17
150
27
2 1,5
25
40
40
18
Ø5
07
e