25
Assembly Instruction
FV1 / FV3 / FV4
Sequence control:
Sequence control:
24V DC
M
24V DC
M
24V DC
M
24V DC
M
n
ote
Installing
M-COM
in a voltage-free state.
The configuration is always in
CLOSE
direc-
tion.
When subsequent programming with
UniPC
the same assembly steps as in the installation
must be carried out with
preprogrammed set
(see separate: Installation Instructions for
UniPC).
Open
Locking drive
Opening
drive
Close
Locking drive
Opening
drive
FV4
FV4
Test run: locking drive
Close the casement manually. During the test run press
the casement fixed to the frame.
Switch on
the
control voltage
at locking drive
FV4
- in
CLOSE
direction.
Switch the control voltage - from the locking drive
FV4
in
OPEN
direction.
Ensure the easy movement of the casement.
Open the casement manually.
Switch off
the
control voltage
from the locking drive
FV4
.
Switch on
the
control voltage
at locking drive
FV4
and at opening drive
-
in
CLOSE
direction.
M-COM
is configured (see LED display).
Check sequence control.
Ensure the easy movement of the casement.
Installation: M-COM
Installing the
M-COM
(see separate „Installation
Instructions“ for M-COM) and make the electrical
connection - in accordance with chapter: „
E
lEctric
connEction
- i
nstallation
stEP
12
“.
Hinge opening drive on casement.
Make mechanical settings in accordance with „Assem-
bly and Commissioning Instructions“ of the drives.
I
nstallatIon
step
10
a
:
I
nstallatIon
step
10
b
:
a
ssembLy
with
m-com
a
ssembLy
oF
a
preprogrammed
set
Open
Locking drive
Opening
drive
Close
Locking drive
Opening
drive
FV3
FV3
Test run and installation: FV3 and opening
drive as a preprogrammed set
Hinge opening drive on casement.
Make mechanical settings in accordance with „Assem-
bly and Commissioning Instructions“ of the drives.
Switch on
the
control voltage
at locking drive
FV3
and at the opening drive - in
CLOSE
direction.
Check sequence control.
Ensure the easy movement of the casement.
Test run: locking drive
Close the casement manually. During the test run press
the casement fixed to the frame.
Switch on
the
control voltage
at locking drive
FV3
and at the opening drive - in
CLOSE
direction.
Move locking drive
FV3
and opening drive in
OPEN
direction.
Ensure the easy movement of the casement.
Open the casement manually.
FV4
FV3
a
nsChlusskabel
unD
DiP-s
Chalter
a
ssembly
with
m-Com
or
a
ssembly
of
a
PreProgrammeD
set
06
FV3
Summary of Contents for FV1
Page 34: ...34 Assembly Instruction FV1 FV3 FV4 08...
Page 36: ...9000018401_V2 0_KW21 22...