20
Assembly Instruction
FV1 / FV3 / FV4
06
r
emoVe
the
end
caps
From
the
Locking
driVe
Loosen the screws
and remove the end caps
from
the locking drive
FVx
.
Remove connection cable (
AK
) for easier handling.
If necessary, prepare end cap
for another cable.
Use screwdriver to pierce the closed drill hole. Remove
the burrs. Possibly slightly enlarge drill hole.
Feeding the cable through the new hole carefully.
Provide strain relief
.
D
rill
holes
aCCorDing
to
mounting
variants
1 2 3 4 5
I
nstallatIon
step
6:
I
nstallatIon
step
7:
d
riLL
hoLes
according
to
mounting
Variants
LO
C
TI
TE
1.
)
2.
)
3.
)
4.
)
5.
)
FL
RA
Determine fastenings.
Produce drill holes with appropriate cross-section.
For the mounting dimensions please refer to the
above-mentioned hole layout drawings (see chapter
„
i
nstallation
stEPE
5
“ or project-specific documents
and drawings).
Secure fasteners against loosening; e.g. by applying
removable thread-locking compound such as “Loctite”.
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
06
FV
x
3
1
2
2
AK
Summary of Contents for FV1
Page 34: ...34 Assembly Instruction FV1 FV3 FV4 08...
Page 36: ...9000018401_V2 0_KW21 22...