Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
– Fit clamps so that ends of bolts do not protrude beyond bottom
of clamp.
• Bolt connections face one another.
– Align exhaust system so it is free of stress
1.3
Removing and installing exhaust pipes
(left-side)
Removing
• Engine removed and in position on scissor-type assembly
platform - VAS 6131 A- with gearbox attached.
Note
♦
Fit all heat shields and heat insulation sleeves in the original
positions when installing.
♦
All cable ties which are released or cut open when removing
must be fitted in the same position when installing.
– Take electrical connector -1- for Lambda probe 3 after catalytic
converter - G287- out of bracket and unplug it.
Note
Ignore items marked -2- and -arrows-.
– Remove bracket for electrical connectors -1 ... 4- for Lambda
probes from subframe -arrow-.
– Take electrical connectors -1- for Lambda probe 4 after cata‐
lytic converter - G288- and -2- for Lambda probe 3 - G285-
(before catalytic converter) out of bracket on gearbox and
unplug.
Audi A8 2003 ➤
10-cylinder direct petrol injection engine (5.2 ltr. 4-valve), mechanics - Edition 10.2013
230
Rep. gr.26 - Exhaust system