Trade name / Models : atlantic / alfea ...
hybrid duo
gaz
11 mono
hybrid duo
gaz
14+ mono
hybrid duo
gaz
11 tri
hybrid duo
gaz
14+ tri
hybrid duo
gaz
16 tri
Reference
522524 /
522197
522525 /
522198
522473 /
522184
522474 /
522185
522475 /
522186
Heating ranges
55°C
55°C
55°C
55°C
55°C
Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Pdh
kW
8.2
10.0
8.2
10.0
11 5
Tj = +2°C
Pdh
kW
5.0
6 1
5.0
6 1
7.0
Tj = +7°C
Pdh
kW
5 9
5 9
5 9
5 9
5 8
Tj = +12°C
Pdh
kW
7.0
7 1
7.0
7 1
7 1
Tj = bivalent temperature
Pdh
kW
8.2
10.0
8.2
10.0
11 5
Tj = operation limit temperature
Pdh
kW
8.0
9 3
8 1
9 3
10.3
Bivalent temperature
T
biv
°C
-7
-7
-7
-7
-7
Degradation coefficient
(3)
Cdh
-
0.9
0.9
0.9
0.9
0.9
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
COP
d
-
1 89
1 89
1.92
1 95
1 83
Tj = +2°C
COP
d
-
2.80
2.77
2.75
2.87
2.89
Tj = +7°C
COP
d
-
3 76
3 89
3 93
4.07
4.12
Tj = +12°C
COP
d
-
4 81
5 11
5 16
5 38
5.50
Tj = bivalent temperature
COP
d
-
1 89
1 89
1.92
1 95
1 83
Tj = operation limit temperature
COP
d
-
1 66
1 67
1 61
1 64
1 63
Air-to-water heat pump: Operation limit temperature
TOL
°C
-10°C
-10°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
80
80
80
80
80
Supplementary heater
Rated heat output
(2)
P
sup
kW
1 3
2.1
1 1
2.0
2.7
Type of energy input
-
-
Fossil
Power consumption in modes other than active mode
Off mode
P
OFF
W
8
8
14
14
14
Thermostat-off mode
P
TO
W
22
25
32
43
32
Standby mode
P
SB
W
12
12
17
17
17
Crankcase heater mode
P
CK
W
0
0
0
0
0
Other items
Capacity control
-
-
Inverter
Nox emission
Nox PCS mg/kWh
55
Air-to-water heat pump, Rated air flow rate
-
m
3
/h
6200
6900
(1)
Seasonal efficiency calculation is detailed in package fiche - room units are available as option and includes: thermostat and
room sensors, room unit controller wether they are, or not, integrated in kits
(2)
For
heat pump space heaters and heat pump combination heaters, the rated heat output
e P
rated
is equal to the design load
for heating P
designh
and the rated heat output of the supplementary heater
P
sup
is equal to the supplementary capacity for heating
sup (Tj).
(3)
If
Cdh is not determinated by measurement then the default degradation coefficient is Cdh=0.9
Installation and commissioning instructions "1485 - EN"
- 87 -
Heat pump alféa hybrid duo gas
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...