L1
L1
L2
L2
90°
90°
figure 20 - Connection possibilities (C13 and C33 type)
C13 type pipe connection
C33 type pipe connection
¤ 90° elbow
= 1 m of straight pipe.
¤ 45° elbow
= 0.5 m of straight pipe.
Existing evacuation pipe.
¤ 45° offset
= 0.5 m of straight pipe.
¤ 30° offset
= 0.3 m of straight pipe.
Maximum straight line length
= 11 m (excluding terminal)
This length must be reduced by 1 m per 90° elbow and 0.5 m per 45° elbow.
Example of C13 type connection with 3 90° elbows: L1 + L2 + L3 + (3 x 1 m)
≤
11 m
Example of C33 type connection with 2 45° elbows: L1 + L2 + L3 + (2 x 0.5 m)
≤
11 m
Example of C33 type connection with Rénolux system:
¤ entry into wall with 2 90° elbows and 2 30° offsets: L1 + L2 + (2 x 1 m) + (2 x 0.3 m)
≤
11 m
¤ entry into wall with 2 30° offsets: L1 + L2 + (2 x 0.3 m)
≤
11 m
RT
- Telescopic pipe.
T
- terminal (max 1 m).
Rénolux system
for adaptation to the existing evacuation pipe.
RT
RT
T
T
L
L1
L2
L3
45°
45°
Mini
16 et 24 kW
1577 mm
34 kW
1698 mm
28 et
5%
5%
L1
L3
L2
90°
90°
90°
5%
L1
L2
90°
5%
1899 mm
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 22 -
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...