Line
Function
Setting range or display
Setting
increment
Basic setting
Diagnostics consumers
8700
U
Outside temperature
-50... 50 °C
--
8701
U
Minimum outside temperature
Reset ? (no, yes)
-50... 50 °C
--
8702
U
Maximum outside temperature
Reset ? (no, yes)
-50... 50 °C
--
8703
I
Attenuated outside temperature
Reset ? (no, yes)
-50... 50 °C
--
This is the average of the outside temperature over a 24-hour period.
This value is used for automatic Summer / Winter switchover (line 730).
8704
I
Mixed outside temperature
-50... 50 °C
--
The mixed outside temperature is a combination of the current outside temperature and the average outside temperature
calculated by the regulator. This value is used for calculating the initial temperature.
8730
I
Circulation pump, circuit 1
Off, On
Not
concerned
8731
I
Mixer valve HC1 open
Off, On
Not
concerned
8732
I
Mixer valve HC1 closed
Off, On
Not
concerned
8740
U
Room temperature 1
0... 50 °C
--
Ambient temperature setting 1
20 °C
8743
U
Flow temperature 1
0... 140 °C
--
Flow temperature setpoint 1
--
8749
I
Room thermostat 1
No demand, Demand
No demand
8756
U
Cooling flow temperature 1
0... 140 °C
--
Cooling flow temperature setpoint 1
--
8760
I
Circulation pump, circuit 2
Off, On
Not
concerned
8770
I
Room temperature 2
0... 50 °C
--
Ambient temperature setpoint 2
20°C
8773
U
Flow temperature 2
0... 140 °C
--
Flow temperature setpoint 2
--
8779
I
Room thermostat 2
No demand, Demand
No demand
8786
U
Cooling flow temperature 2
Cooling flow temperature setpoint 2
8820
I
DHW pump
Off, On
Off
8830
U
DHW (domestic hot water) temperature
0... 140 °C
--
DHW temperature setpoint
50 °C
8840
S
DHW pump operating times
0... 2730 h
--
8841
S
DHW pump start-ups counter
0... 199999
--
8842
S
DHW electric operating times
0... 2730 h
--
8843
S
DHW electric start-ups counter
0... 65535
--
8950
I
Common flow temperature
0... 140 °C
--
Common flow temperature setpoint
--
Installation and commissioning instructions "1485 - EN"
- 67 -
Heat pump alféa hybrid duo gas
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...