UE
VE
VD
Cd
SSa
BS
Pg
Pg
SSu
SD
C
CAR
CPr
EG
C
EG
SR
EG
SD
EG
SR
GS
MT
CAR
D
RI
°C
R
SA
VM
SDp
SP
CCM
SA2
CAR
CAR
PC
M
kit PCBT /2 circuits
1
2
•
Configuration 10 : 2 heating circuits (rad heating floor system)
Caption :
BS
- Domestic hot water tank
CAR
- Non-return valve
C
- Circulating pump ( DHW and direct circuit "CC2")
CC / CCM
- Mixing circuit pump (CC1)
Cd
- Condenser
C
EG
- Circulating pump gas burner chamber
CPr
- Hydraulic pressure sensor
D
- Backflow preventer
EG
- Gas burner chamber
GS
- Safety unit (Not supplied / required)
MT
- Thermostatic mixing valve
PC
- Heating floor system
Pg
- Air bleeder
R / R2
- Radiators
SA1
- Room sensor mixing circuit "CC1" (optional)
SA2
- Room sensor direct circuit "CC2" (optional)
SD
- Flow sensor
SD
EG
- Flow sensor gas chamber exchanger
SDp
- Flow sensor mixing circuit
SP
- Heated floor safety fuse
SR
- Return sensor
SR
EG
- Return sensor gas chamber exchanger
Ssa
- DHW sensor
SSu
- Safety valve
UE
- Outdoor unit
VD
- Distribution valve
VE
- Expansion vessel
VM
- Mixing valve
Installation and commissioning instructions "1485 - EN"
- 35 -
Heat pump alféa hybrid duo gas
SA1
SA2
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...