2 Installation
2 .1 Installation and maintenance rules
The appliance must be installed and the maintained
by an approved professional in accordance with the
prevailing regulations and code of practice, in particular:
-
The legislation on the handling of refrigerants.
-
Heating installation with floor heating system.
-
Low voltage electrical installations - Rules.
2 .2 Unpacking and reserves
2 .2 .1 Reception
When the courier is present, carefully check the general
appearance of the appliances, check that the outdoor
unit has not been in horzontal position. In the event
of disagreement, write to the courier within 48 hours
mentioning all reserves and send a copy of this letter to
the After Sales Department.
2 .2 .2 Handling
The outdoor unit must not be in horizontal position during
transport. Transport in a horizontal position creates risk
of damage to the appliance by moving the cooling fluid
and damaging the compressor's suspension.
Damage caused by transport transport in horizontal
position is not covered by the warranty.
If required, the outdoor unit may be tilted only when
being moved by hand (to get it through a doorway, or
up stairs...). This operation must be carried out carefully
and the appliance must be immediately returned to the
vertical position.
2 .2 .3 Containment of refrigerant circuits
All refrigerant circuits fear contamination from dust and
moisture. If such pollutants introduced into refrigeration
circuit, they can contribute to degrade the reliability of
the heat pump
"
It’s necessary to ensure correct containment
connections and refrigerant circuits (hydraulic
unit, outdoor unit).
"
In case of subsequent failure and expertise, the
finding of the presence of moisture or foreign
objects into the compressor oil would lead to
systematic exclusion of warranty.
-
Check upon receipt that the fittings and the refrigeration
circuit caps mounted on hydraulic unit and outdoor unit
are properly seated and locked (impossible to loosen
bare hands). If this’s not the case, tighten them using
an against wrench.
-
Check also that the refrigerant connections are sealed
(plastic caps or tubes crushed at the ends and soldered).
If the caps must be removed during installation (tubes
cut by example), put back them as soon as possible.
Installation and commissioning instructions "1485 - EN"
- 15 -
Heat pump alféa hybrid duo gas
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...