Electrical wiring diagrams
figure 60 - Outdoor unit electrical cabling (alféa hybrid duo gas 11 & 14+ single phase)
WOYG112LBT / WOYG112LCT
WOYG140LBT / WOYG140LCT
Thermistor
(expansion)
Expansion
valve coil
(Injecrtion)
Thermistor
(pipe)
Thermistor
(pipemid)
Thermistor
(discharge)
Thermistor
(outdoor)
Thermistor
(compressor)
Pressure
sensor
Choke coil
Posistor
Solenoid
coil
Solenoid
coil
Expansion
valve coil
Fan motor 1
(upper)
Fan motor 2
(lower)
Option(connector)
Refer to the
technical manual
Fuse
Fuse
Power source
230 V
Interconnection
between the outdoor unit
and the hydraulic unit
F4 T 5A - 250 V
F2 T 3,15A - 250 V
Fuse
10A
Relay
Diode bridge
Terminal
Earth
Earth
Terminal
Terminal
Compressor
Active
Filter
Module
Printed Circuit Board
(Main)
Printed Circuit Board
(Disply)
Printed Circuit Board
(Filter)
Thermistor
(heat sink)
Color Codes
BK Black
BN Brown
BU Blue
GN Green
GY Grey
OG Orange
RD Red
VT Purple
WH White
YE Yellow
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 70 -
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...