www.atestgaz.pl
8.5
Periodical opera!ons
It is recommended to perform interface test (see sec on 5.4) once a week.
It is recommended to perform output test (see sec on 5.9) once a month.
8.5.1
Replacement of consumables
The life cycle of consumables/ wearing components is presented in table 16.
To replace a discharged ba+ery or a burned fuse, take the following steps:
1. disconnect power supply from the control unit,
2. remove unit cover,
3. disconnect the front panel by unplugging the connector (see figure 2),
4. remove the discharged ba+ery from the ba+ery port or a burned fuse from the fuse seat (see
figure 2),
5. install a new ba+ery or a fuse (for component types – see table 16),
6. connect and replace the unit cover,
7. connect power supply to the control unit.
8.5.2
Maintenance
Except for cleaning the external surface of unit housing, no special unit maintenance is required. Clean the
external unit housing with a non-abrasive cloth moistened with water and some so detergent.
8.6
U!liza!on
This symbol on the product or its packaging indicates that this product
must not be disposed of with other household waste. Instead, it is user’s
responsibility to dispose of your waste equipment by handing it over to a
designated collec on point for the recycling of waste electrical and
electronic equipment. The separate collec on and recycling of your
waste equipment at the me of disposal will help conserve natural
resources and ensure that it is recycled in a manner that protects human
health and the environment. For more informa on about where you can
drop off your consumer waste equipment for recycling, please contact
your local city recycling office, waste collec on company or the dealer
from whom you originally purchased the product. The product can be
also returned to its manufacturer.
9
Troubleshoo!ng
9.1
Clock not set
In case the control unit signals “Clock not set” replace the ba+ery and update the date and me seNngs
(see sec on 8.5.1).