Input-output interfaces
The interfaces are available on a terminal strip accessible afar front panel removal and on its bo+om wall.
The descrip on of terminal strip is presented in figure 3 and table 1. For Extension Module interface
descrip on – see sec on 4.6, or service interface – see sec on 4.5.
Port symbol
Terminal
no.
Terminal
name
Descrip!on
Device 230 V AC power supply port. Parameters – see sec on 10
1
L
Phase wire
2
N
Neutral wire
3
PE
Protec ve earth wire
All-purpose relay port. For further informa on – see sec on 4.2
4
COM
Common terminal of relay
5..7
R1..R3
Normally open contact of relay 1...3
Fault relay. For further informa on – see sec on 4.1
8..9
F1..F2
Fault relay NC terminals
External signal dual input. For further informa on – see sec on 4.3
10
D1..D2
Digital input terminals – bidirec onal polarity
24 V DC power supply port. Parameters – see sec on 10
12
-
Nega ve power supply pole
13
+
Posi ve power supply pole
24 VDC indicator port. For further informa on – see sec on 4.4
14
-
Nega ve indicator power supply terminal
15
Visual indicator power supply output
16
Acous c indicator power supply output
Bus detector port
17
-
Nega ve indicator power supply terminal
18
+
Posi ve indicator power supply terminal
19
E
Cable shielding
20
A
Signal line A
21
B
Signal line B
Table 1: Terminal strip descrip!on
p. 9|37
User's Manual: POD-026-ENG R11
Figure 3: Terminal strip