Astraada DRV-24 frequency inverters Keypad operation procedure
25
2) This function code is not modifiable in running state, but modifiable in stop state.
Example: Set function code P00.01 from 0 to 1.
Figure 4-3 Sketch map of modifying parameters
4.3.2 How to set the password of the inverter
Astraada DRV-24 series inverters provide password protection function to users. Set P7.00 to gain
the password and the password protection becomes valid instantly after quitting from the function
code editing state. Press PRG/ESC again to the function code editing state, “0.0.0.0.0” will be
displayed. Unless using the correct password, the operators cannot enter it.
Set P7.00 to 0 to cancel password protection function.
The password protection becomes effective instantly after retreating from the function code editing
state. Press PRG/ESC again to the function code editing state, “0.0.0.0.0” will be displayed. Unless
using the correct password, the operators cannot enter it.
Figure 4-4 Sketch map of password setting
4.3.3 How to watch the inverter state through function codes
Astraada DRV-24 series inverters provide group P17 as the state inspection group. Users can enter
into P17 directly to watch the state.
Figure 4-5 Sketch map of state watching
5 Function Parameters
The function parameters of Astraada DRV-24 series inverters have been divided into 30 groups
(P00~P29) according to the function, of which P18~P28 are reserved. Each function group contains
certain function codes applying 3-level menus. For example, “P08.08” means the eighth function
code in the P8 group function, P29 group is factory reserved, and users are forbidden to access
these parameters.
For the convenience of function codes setting, the function group number corresponds to the first
level menu, the function code corresponds to the second level menu and the function code