TeleBoss 850 2.06.280_STD User Manual
Page 59
The most you can do to restrict what information the Audit Log contains is to disable the Audit Log by setting
audit.log.enable
to OFF, also in Setup Menu -> Audit Log and the Logs -> Audit Log portion of the Web UI.
Nothing goes in the Audit Log when it is disabled. If you want some information to go in the Audit Log then configure
the settings for the kind of information you want logged.
Restrict which users have access to the Audit Log by changing their file permissions. There are two permissions:
read (a.k.a. release) and write (a.k.a. delete), which are accessible with
sec.user[x].audit.readaccess
and
sec.user[x].audit.writeaccess
, also available in the Setup Menu -> Security -> Specific Security -> User
Profile x -> File Release Permissions/File Delete Permissions, and the Security -> User Profiles -> User Profile x ->
File Release/Delete Permissions portion of the Web UI. The possible values for these settings are ALLOW and
DENY.
The FTP Push settings are writable by a user with ADMIN1 rights or greater. Restrict which user(s) have ADMIN1
rights in order to prevent users who would ordinarily not have permissions to view the Audit Log to configure the unit
to FTP-push the Audit Log to some server where that user could read them.
Scripting Settings
Scripting is a T850
feature that is complex enough that it has been given it’s own chapter in this User Manual. The
initial Scripting Settings menu is displayed below, but a full description of the options along with other information
necessary to use the scripting functions can be found in the
TeleBoss 850 - Scripting Settings
A) Enable Scripting [OFF]
B) Clear Pending Records [0]
C) DTR Override Ports
D) List Allocated Devices
E) List Scripts
F) Manage Script Files
Summary of Contents for Teleboss 850