![Asentria Teleboss 850 User Manual Download Page 119](http://html.mh-extra.com/html/asentria/teleboss-850/teleboss-850_user-manual_2981745119.webp)
TeleBoss 850 2.06.280_STD User Manual
Page 113
Incoming records
0000001 N 019 00 DN1042 T001034 02/25 09:21 00:00:50 A 5558481677
0000002 N 020 00 DN5280 T001033 02/25 09:22 00:00:08 A 5551377443
0000003 N 021 00 T002014 DN6502 02/25 09:22 00:00:10
0000004 N 022 00 T007002 DN5700 02/25 09:19 00:02:36
0000005 E 023 00 T002024 DN1006 02/25 09:22 00:00:58
0000006 N 024 00 T002042 DN6000 02/25 09:21 00:00:46
0000007 N 025 00 DN5154 T001035 02/25 09:04 00:17:50 A 5558451000
0000008 N 026 00 DN1192 T001031 02/25 09:22 00:01:10 A 5558406776
0000009 N 027 00 DN1048 T001034 02/25 09:23 00:00:26 A 5556426898
0000010 N 028 00 DN1197 T001020 02/25 09:19 00:04:30 A 5552550948
0000011 N 029 00 DN6063 T001033 02/25 09:23 00:00:16 A 5557458535
0000012 N 030 00 T002019 DN6447 02/25 09:23 00:00:10
Alarm records
0000001 N 019 00 DN1042 T001034 02/25 09:21 00:00:50 A 5558481677 (DA 1)
0000001 N 019 00 DN1042 T001034 02/25 09:21 00:00:50 A 5558481677 (DA 2)
0000011 N 029 00 DN6063 T001033 02/25 09:23 00:00:16 A 5557458535 (DA 1)
The first record matches data alarm 1, because macro 'm1' is true. Macro 'm1' is true any time the character in
the 7th position is '1'.
The first record also matches data alarm 2, because macro 'm1' is true and field 'f2' contains a '0' character.
The eleventh record matches data alarm 1, again because macro 'm1' is true. It does not match data alarm 2
because field 'f2' does not contain a '0' character.