Note:
Boot Load Mode can only be set by flipping ALL DIP switches to the UP position. This is not a setting that
can be configured via internal menu settings, or Setting Keys.
Note:
For settings that can be set either via DIP switch, internal menu settings, or Setting Keys, the T850 always
pays attention to the last setting, regardless of how it was done. So if the internal setting for I/O 2 Port Mode is
Command, and someone flips SW4 to the UP position, the Mode is immediately set to Data.
Buttons
The only button on the T850 is the Reset button located on the back panel next to the left of serial port I/O 2. The
Reset button can be used for two different functions:
1) To reset the T850
– press the Reset button for approximately 1 second and T850 will be begin the reboot
2) To activate the
feature which resets the username and password back to default.