11
Rev 2, 18.06.19
RECIPE SCREEN DEFINED continued
Air Cycling:
If the icon is green and the frame flashing, this indicates that the air inside the unit is
being equalized to reduce cool/warm spots. All functions will be disabled for a set
period of time. It is normal for the temp and humidity to go out of range during this
time. The same key gives you the possibility of disabling or forcing an air cycle.
Cooling:
If the icon is green and the frame flashing, this indicates that cooling system is
working to bring the temp down to the set point. The same key gives you the
possibility of disabling or forcing the action.
Heating:
If the icon is green and the frame flashing, this indicates that the heating system is
working to bring the temp up to the set point. The same key gives you the possibility
of disabling or forcing the action.
Humidification:
If the icon is green and the frame flashing, this indicates that humidification system is
working to bring the RH up to the set point. The same key gives you the possibility of
disabling humidification.
Note when the unit needs to dehumidify, the humidification
icon will change to the dehumidification icon.
Dehumidification:
If the icon is green and the frame flashing, this indicates that dehumidification system
is working to bring the RH down to the set point. The same key gives you the possibility
of disabling dehumidification.
Note when the unit needs to humidify, the dehumidifi-
cation icon will change to the humidification icon.
Fan low/high speed:
If this icon is green with the green frame flashing, this indicates that the fan is working
at a low speed; if the icon is blue with blue flashing frame, this indicates that the fan is
working at a high speed.
Note you can toggle between high and low speed setting
simply by pressing the fan icon.
Rest/Recovery:
If the icon is green and the frame flashing, this indicates that the Maturmeat® has
disabled all functions for a set period of time to allow the product inside to rest. It is
normal for the temp and humidity to go out of range during this time. The same key
gives you the possibility of disabling or forcing the action.
Internal Light:
If the icon is light blue and the frame flashing, this indicates the light inside the unit is
switched on.
Defrost:
If the icon is green and the frame flashing, this indicates that the evaporator probe
has detected a temp (set in the system variables) and has triggered a defrost. All
functions will be disabled during the defrost period. It is normal for the temp and
humidity to go out of range during this time. The same key gives you the possibility of
disabling or forcing the action.
Aroma:
If the icon is green and the frame flashing, this indicates that liquid is drawn out of the
aroma tank by the Fumotic
®
, nubulized and sprayed into the unit. The same key gives
you the possibility of disabling or forcing the action.
Summary of Contents for Maturmeat 100