10
Rev 2, 18.06.19
2.3
RECIPE SCREEN DEFINED
Yellow value can be changed for the duration of the phase only, default values will reset once recipe
advances into the next phase, if recipe is exited and re-entered, or if power loss occurs.
The following is an explaination of the recipe screen to help you understand the parameters you
will be interacting with daily on the Maturmeat
®
controller. Alternatively, use the link to see the
video online
https://www.youtube.com/watch?v=AfhtshDWTdI
NOTE
PH
5.6
SET
POINT
5.8
HUMIDITY
75
%
SET
POINT
81%
TEMPERATURE
1.3˚C
SET
POINT
1.0˚C
12:35
24/03/2018
AGED BEEF
Current Recipe
TOTAL TIME
999 Hrs
REMAING TIME
999 Hrs
MATURING
PHASE 1 OF 1
TOTAL TIME
999
REMAING TIME
999
AGED BEEF
Current Recipe
TOTAL TIME
999 Hrs
REMAING TIME
999 Hrs
Start/Pause Recipe:
Icon Light Blue = recipe is working.
Icon Grey = recipe is paused.
Recipe name currently in use.
Total time of the current recipe in use.
Remaining time of the recipe in use.
Recipe phase currently preforming
WHITE VALUE: displays time remaining
in current phase.
YELLOW VALUE:
displays total time in
current phase.
Relative Humidity for current phase
WHITE VALUE: displays current humidity
inside unit.
YELLOW VALUE:
displays humidity set
point needed to be reached.
Note: set yellow value to 0 to skip phase when necessary.
Note: There is +/- 7 range. Temp must be achieved before
any other functions will work. It is normal to see humidity go
out of range during cooling/heating.
MATURING
PHASE 1 OF 1
TOTAL TIME
999
REMAING TIME
999
75%
HUMIDITY
81%
SET
POINT
Home icon: has 2 functions, exit recipe
(when recipe is paused), check VTE/VTC
values (while recipe is working).
Cleaning In Place (C.I.P.): a 2 stage
recipe for internal washing and drying of
the chamber.
Note: remove all foodstuff before starting.
SET
POINT
PH
5.6
5.8
pH for current phase (guide only)
*WHITE VALUE: displays current pH
value inside unit.
YELLOW VALUE:
displays ideal value
to be reached.
Temperature for current phase
WHITE VALUE: displays current temp
inside unit.
YELLOW VALUE:
displays temp set
point needed to be reached.
Note: There is +/- 2 range. Temp must be achieved
before any other functions will work. It is normal to see
humidity go out of range during cooling/heating.
*This value can only be read when pH probe has been
purchased and connected.
1.3˚C
TEMPERATURE
1.0˚C
SET
POINT
Shows GSM connection strength in blue,
icon will be grey without connection.
Link turns blue only when a live connection
exists between controller and our server,
otherwise icon will be grey.
Turnes
blue
when
downloading
firmware, otherwise icon will be grey.
Note: In order for the Link icon to be active, you must add
a GSM sim card to the controller.