37
Rev 2, 18.06.19
Variable
Description
Value
Drainage duration (minutes)
At the end of the defrost cycle, cooling, dehumidification
and fan systems are stopped for the set SGO time.
Min 1 minute
Max 60 minutes
0 min.....20 min
0 DISABLED
DS
FAN PAUSE
After defrosting and after draining (if set in SGO ), the delay
countdown begins.
Interval set in hours between defrost periods.
Defrost temperature.
Defrosting is carried out until the temperature read by
the evaporator probe is achieved (if the probe fails to read
temp, the defrost is completed with the DS set time)
0h.....24h
0 DISABLED
-50°C.....+100°C
0 min.....20 min
0 DISABLED
IS
PV
SGO
TS
Maximum defrost duration (minutes).
Default
2h
20 min
10°C
5 min
0 min
ABT
Low temperature alarm
This allows a minimum ambient temperature value to be
defined. An alarm will be set off below the ABT
temperature; the alarm will appear onscreen, and an
audiable beep will sound the existence of the anomaly.
The alarm is triggered after the RAT time.
ABT <-50°C = OFF
ABT<AAT by 1.0
-4°C
High temperature alarm
This allows a maximum ambient temperature value to be
defined. An alarm will be set off above the ABT
temperature; the alarm will appear onscreen, and an
audiable beep will sound the existence of the anomaly.
The alarm is signalled after the RAT time. The alarm does
not interrupt any defrosts in progress.
Low humidity alarm
This allows a minimum humidity value to be defined for
the space to be humidified. The alarm is activated below
the ABU value, the alarm will appear onscreen, with an
audiable beep. The alarm is triggered after the RAU time.
AAT>200°C = OFF
AAT>ABT by 1.0
ABU<AAU by 1%
ABU< 1%=OFF
AAT
ABU
4°C
0%
HIGH humidity alarm
This allows a maximum humidity value to be defined for
the ambient to be humidified. The alarm is activated above
the AAU value, the alarm will appear onscreen, with an
audiable beep. The alarm is triggered after the RAU time.
AAU>ABU by 1%
AAU >99%=OFF
AAU
100%
SYSTEM VARIABLES continued