![Areca ARC-5030 Series User Manual Download Page 60](http://html1.mh-extra.com/html/areca/arc-5030-series/arc-5030-series_user-manual_2966539060.webp)
LCD CONFIGURATION MENU
60
4.7 Using Raid Set and Volume Set Func-
tions
In Raid Set Function, you can use the Create Raid Set function to
generate the new raid set. In Volume Set Function, you can use
the create volume set function to generate its associated volume
set and parameters. If the current controller has unused physical
devices connected, you can choose the Create Hot Spare option in
the Raid Set Function to define a global hot spare.
Select this method to configure new raid sets and volume sets. This
configuration option allows you to associate volume set with partial
and full raid set.
Step
Action
1
To setup the Hot Spare (option), choose
Raid Set Function
from the
main menu. Select the
Create Hot Spare
and press
Enter
key to set the
Hot Spare.
2
Choose Raid Set Function from the main menu. Select the Create Raid
Set and press Enter key.
3
Select a Drive For Raid Set window is displayed showing the IDE drive
connected to the current controller.
4
Press
UP
and
DOWN
arrow keys to select specific physical drives. Press
the
Enter
key to associate the selected physical drive with the current
raid set.
Recommend use drives has same capacity in a specific raid set. If you use
drives with different capacities in an array, all drives in the raid set will
select the lowest capacity of the drive in the raid set.
The numbers of physical drives in a specific raid set determine the RAID
levels that can be implemented with the raid set.
RAID 0 requires 1 or more physical drives per raid set.
RAID 1 requires at least 2 physical drives per raid set.
RAID 1 + Spare requires at least 3 physical drives per raid set.
RAID 3 requires at least 3 physical drives per raid set.
RAID 5 requires at least 3 physical drives per raid set.
RAID 6 requires at least 4 physical drives per raid set.
RAID 3 + Spare requires at least 4 physical drives per raid set.
RAID 5 + Spare requires at least 4 physical drives per raid set.
RAID 6 + Spare requires at least 5 physical drives.
5
After adding physical drives to the current raid set as desired, press Yes
to confirm the Create Raid Set function.
6
An Edit The Raid Set Name dialog box appears. Enter 1 to 15 alphanu-
meric characters to define a unique identifier for a raid set. The default
raid set name will always appear as Raid Set. #. Press Enter to finish the
name editing.
Summary of Contents for ARC-5030 Series
Page 11: ......