![Areca ARC-5030 Series User Manual Download Page 151](http://html1.mh-extra.com/html/areca/arc-5030-series/arc-5030-series_user-manual_2966539151.webp)
151
WEB BROWSER-BASED CONFIGURATION
• Tag Queuing
The Enabled option is useful for enhancing overall system per-
formance under multi-tasking operating systems. The Command
Tag (Drive Channel) function controls the SCSI command tag
queuing support for each drive channel. This function should
normally remain enabled. Disable this function only when using
older SCSI drives that do not support command tag queuing.
• Max SCSI Speed
The RAID subsystem supports 320.00 MB/sec ......as the highest
data transfer rate.
• SCSI Channel/SCSI/ID
SCSI Channel:
The RAID subsystem only supports one SCSI
Channel.
SCSI ID:
Each SCSI device attached to the SCSI card, as well
as the card itself, must be assigned a unique SCSI ID number. A
Wide SCSI channel can connect up to 15 devices. The RAID sub-
system is as a large SCSI device. We should assign an ID from a
list of SCSI IDs.
SCSI LUN:
Each SCSI ID can support up to 8 LUNs. Most SCSI
host adapter treats each LUN like a SCSI disk.
6.9.1.2 For ARC-5030
The following is the volume set features for the ARC-5030
1. Volume sets of different RAID levels may coexist on the
same raid set.
2. Up to 16 volume sets in a raid set can be created by the
SATA RAID controller.
3. The maximum addressable size of a single volume set is 2
TB.
4. Support greather than 2TB capacity per volume set (64-bit
LBA mode).
To create volume set from raid set system, move the cursor bar
to the main menu and click on the Create Volume Set link. The
Select The Raid Set To Create On It screen will show all raid set
number. Tick on a raid set number that you want to create and
then click on the Submit button.