TE
CH
NI
CA
L S
PE
CIF
ICATI
ON
6.3
Operation / Performance
General usage
Aquacell Wastewater Samplers are NOT
suitable for use in areas which have been
classified as ATEX hazardous zones
Sample media suitability
Non-pressurised wastewater (unless specified
with Pressurised Pipeline Interface)
Sample extraction method
Air pump vacuum system
Operating modes
Time 1 min to 100 hour sampling interval
Flow
Volt-free impulse or 4-20mA
Event Externally triggered e.g. by pH meter
Maximum lift height
> 7 metres
Transport velocity
On Mains AC = 0.5 m/s average over 7m
On 12VDC = 0.5m/s average over 5m
Sample shot volume range
30-500ml (30-100ml when used with 12 Bottle
Removable Bottlers, 30-300ml with PPI)
NOTE: Minimum volume may vary subject to application and Sample Chamber Top configuration
Sample shot cycle time
Approx. 30 seconds (with 4 metres lift)
Data logging
Up to 1012 events can logged and viewed on
the Samplers LCD or downloaded via the
optional Data Connection (CL-4006).
Sample temperature can also be logged
/ downloaded when an optional Sample
Temperature Monitoring connection is
specified
Intake Hose
2m flexible braided PVC hose with Stainless
Steel Intake Filter incorporating 5 x
Ø
12mm
intake ports
2m Intake Hose Extensions as required
Intake Hose purging
Air / residual effluent purging before and
after sample intake
Sample tract diameter
12mm increasing to 16mm (22mm when bottler
is in use) between sample intake and sample
discharge
Maximum sample media temperature
60°C
Summary of Contents for Aquacell P2 Series
Page 1: ...AQUACELL PORTABLE WASTEWATER SAMPLERS USER GUIDE Sira MC 050059 Issue 20 2...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ...CONTENTS OF PACKAGE 1 2...
Page 14: ...CONTENTS OF PACKAGE 1 8...
Page 16: ...INTRODUCTION 2 2...
Page 26: ...INSTALLATION 3 2...
Page 36: ...INSTALLATION 3 12...
Page 38: ...OPERATION 4 2...
Page 56: ...OPERATION 4 20...
Page 58: ...MAINTENANCE 5 2...
Page 70: ...TECHNICAL SPECIFICATION 6 2...
Page 77: ......