AP006 P44
D
FITTING OF END TRAVEL PLATES
The ONDA 500 / ONDA 800 is fitted with mechanical limit switch with a spring
rod. It is activated by two metal plates (D3) that are fitted on the rack and come
into contact with the switch in the fully open and fully closed gate positions
(D4).
When fitting, remember a few important rules:
-
A safety distance must be maintained between the gate and the posts,
that must comply with the existing safety regulations.
-
It is better to adjust the control unit to avoid violent braking; this will reduce
noise and vibrations which can quicken the wear of the mechanical
members, of the pinion and of the rack.
ATTENTION
The gate must never, for any reason, knock against the mechanical
stops, when opening or closing, it should ALWAYS stop before these.
D 3
FIXING MODES
On the plastic rack:
Dowel M6
Predrilling data:
bore dia : ø 3,9 mm ( standard)
Use ø 3,5 mm drill - min. depth 18 mm
On the steel rack:
Either like for the plastic rack, or by welding.