AP006 P42
D
CONNECTIONS OF THE CONTROL UNIT T2B
The ONDA 500 / ONDA 800 can be controlled by the Aprimatic T2B control units.
In D2 the two connecting terminal-board of the ONDA 500 / ONDA 800 are shown, as to be used with external control unit.
The T2B control unit can be also installed inside the geared motor; in these case see further instruction in appendix.
The motor connections and those of the end sensor signals may be inverted, this is to ensure the correct direction of the movement for the opening and closing
commands, as well as the correct timing of the limit switches.
ATTENTION
The connections shown with a double arrow (
↔
) relative to the motor and the limit switch vary according to the gate sliding direction and depending
on this, may or may not be inverted. To establish the correct wiring, tests can be made when the control unit starts up. At the end of the connection
protect the connecting terminals with the supplied pressure cover.
Do not move the plastic dividers which divide the low voltage area from the high voltage area.
D 2
1
Blue (common)
)
Brown/Black (open/close)
3
Black/Brown (close/open)
4
Black (common)
5
Violet/White (open/close)
6
White/Violet (close/open)
7
8
/
Black /
9
Violet /
10
/
White /
11
Close
12
/
Open