2.2 ASSEMBLY
It is not necessary to drill any holes to fit the device.
1.
Secure the device at a minimum height of 30 cm, using the securing holes in the
plastic container.
2.
Insert the connecting cables, through the holes in the bottom of the container and
the cable clamps indicated.
3.
Fit a multipole switch upstream of the device.
4.
Fit an emergency pushbutton in a position where the automation system can be
seen and so that the power supply to the system can be completely cut-off.
5.
Use 1.5 mm² section cables for the motor power supply and 0.75 mm² section
cables for 24 VDC devices.
2.3 ELECTRICAL CONNECTIONS
CAUTION - Make sure that the mains power supply is turned OFF before making the
connections.
CAUTION - Do not use intercom or telephone cables.
Make the electrical connections as indicated in the diagram alongside.
N.B. In accordance with the current standards, tie the connecting cables for the
different commands separately (terminals 1-11) from the power cables (terminals
12-16).
3. STARTING UP
After completing the connections as indicated and checking the electrical connections
carefully, turn ON the mains power supply and check that the system is functioning
correctly, as explained below.
3.1 FUNCTIONING TESTS
When all the connections have been made, it is necessary to check the automation
system. Due to the type of functioning of the T2 card, when the first Start pulse is given
after Power Up or restoration of the power supply, if the gate is at a standstill but not in
the open or the closed position and the safety devices are not tripped, the gate is
automatically closed. If, on the contrary, the gate opens, the motor connections must be
inverted.
T2-MORS.EPS
N.B. If the terminal safety contacts 2 and 4 (stop input) and terminals 2 and 5 (photocell
input) are not used, jumpers must be fitted.
The function of terminal input N. 6 depends on the setting of the dip switches or
the logic selected and switches from N.O to N.C.
- 24 V Common
Start
Stop
Photocell
Closing input in Dead man mode
Open limit switch
Max. 3 W warning light
LED
Opening
Closing
Common
Neutral
Phase
Protect with differential switch
6 A overload 30 mA
Close limit switch
Capacitor
Device earth connection
Connect motor earth to the device earth connection
230 V flashing unit
Caution. Preflashing
not available.
N.C. contact = Opening safety device in
the following modes: Automatic,
Semiautomatic with stop and Automatic
with stop.