AP006 P28
C
C 5
C 6
C 7
B - SECURING WITH A FOUNDATION PLATE
The securing with a foundation plate requires the positioning of a foundation,
ex novo, where the plate is embedded.
ATTENTION
Position the foundation plate with the cable hole placed adequately with
the correct direction of the gate opening (see C2 at page 23).
Foundation plate positioning
-
Execute a hole for the fitting of the cables for 30 mm diameter tubes MAX.
in connection with the slot in the foundation plate.
-
Fold the four straps of the foundation plate in the way indicated in C5.
-
Fill the hole with good quality cement, insert the plate in the hole and check
the perfect positioning and aligning of the plate with the gate (C6
➀
).
ATTENTION
The surface of the foundation plate must be protected with Zinc spray
or rust inhibitor paint.
Fitting the sliding plate
-
Clean possible cement splashes or rust on the surface of the plate,
specially on the reference marks (C6
➁
).
-
Position the sliding plate in connection with the reference marks (C6
➁
)
and align it at the correct distance from the gate (C7).
-
Weld ONLY on the shorter sides.
ATTENTION
Protect the welds and the projecting part of the foundation plate with
Zinc spray.