MEAS:VOLT:AC:SUM:SQ?
Request for sum of square voltages.
MEAS:VOLT:AC:DIST?
Request for the distortion of measured voltage.
MEAS:VOLT:AC:TR:RAT?
Transformer Test: Request for the measured transmission ratio of separate voltage channels (
r
Lx/L1
).
MEAS:VOLT:AC:TR:ERR?
Transformer Test: Request for the calculated transmission error of separate voltage channels (
er
Lx/L1
).
MEAS:VOLT:AC:TR:PHAS?
Transformer Test: Request for the measured phase error of separate voltage channels (
φ
Lx/L1
).
MEAS:VOLT:AC:TR:RNOM?
Transformer Test: Request for the nominal transmission voltage ratio.
MEAS:VOLT:FREQ?
Request for the measured voltage frequency value.
MEAS:CURR:AC?
Request for current values.
MEAS:CURR:AC:PHAS?
Request for phases between current and voltage in each phase.
MEAS:CURR:AC:SUM:SQ?
Request for sum of square currents.
MEAS:CURR:AC:DIST?
Request for the distortion of measured current.
MEAS:CURR:AC:TR:RAT
Transformer Test: Request for the measured transmission ratio of separate current channels (
r
Lx/L1
).
MEAS:CURR:AC:TR:ERR
Transformer Test: Request for the calculated transmission error of separate current channels (
er
Lx/L1
).
MEAS:CURR:AC:TR:PHAS
Transformer Test: Request for the measured phase error of separate current channels (
φ
Lx/L1
).
MEAS:CURR:AC:TR:RNOM
Transformer Test: Request for the nominal transmission current ratio.
MEAS:POW:AC[:ACT]?
Request for active power values.
MEAS:POW:AC:REAC?
Request for reactive power values.
MEAS:POW:AC:APP?
Request for apparent power values.