![Applent Instruments Anbai AT8612 User Manual Download Page 20](http://html.mh-extra.com/html/applent-instruments/anbai-at8612/anbai-at8612_user-manual_2954893020.webp)
20
AT8612 User's Guide
the load current will be limited to I-MAX , load over current alerts, current value glitters
(but the buzzer does not beep). Load will work in the OC protection state.
2.8
Over Power
CV mode:
If the input power exceeds the power limit (101%*P-MAX), load will work under over-
power protection state and the buzzer beeps, current value flashed and [OP] displayed.
If the input power exceeds the power limit (102%*P-MAX), load will be turned off.
CC, CP and CR mode:
If the input power exceeds the power limit (102%*P-MAX), load will work under over-
power protection state and voltage and current value flashed, but the buzzer is silent.
2.9
Reverse Voltage
This feature protects the load module in case of the input DC voltage lines are connected
with wrong polarity.
Once the reverse voltage condition detected, buzzer beeps and [RV] displayed, and input
will be turned off immediately.
2.10
Over Heat
Once the load internal power devices’ temperature exceeds the safe limits (80
C), load
input will be turned off, [OH] will be displayed and buzzer beeps.