Programming with GPIB Commands
2-4 Parameter and Data Entry Commands
MG369xC GPIB PM
PN: 10370-10374 Rev. F
2-7
PR
Opens the internal pulse
frequency parameter.
5.96 Hz to 25 MHz at 100 MHz pulse clock rate;
2.385 Hz to 4 MHz at 40 MHz pulse clock rate;
0.597 Hz to 1.66 MHz at 10 MHz pulse clock
rate
MH, KH, HZ
PSO
Opens the phase offset
parameter.
-360 to +360
DG
PVT
Opens the ALC power slope
pivot point frequency
parameter.
Frequency range of the MG369xC model
GH, MH, KH, HZ
PW
Opens the internal pulse
width1 parameter
(Same as W1).
30 ns to 167 ms at 100 MHz pulse clock rate;
25 ns to 419 ms at 40 MHz pulse clock rate;
100 ns to 1.6 s at 10 MHz pulse clock rate
SEC, MS, US, NS
SDD
Opens the internal pulse
stepped delay mode step
size parameter.
0 ms to 167 ms at 100 MHz pulse clock rate;
0 ms to 419 ms at 40 MHz pulse clock rate;
0 s to 1.6 s at 10 MHz pulse clock rate
SEC, MS, US, NS
SDE
Opens the internal pulse
stepped delay mode delay1
stop parameter.
0 ms to 167 ms at 100 MHz pulse clock rate;
0 ms to 419 ms at 40 MHz pulse clock rate;
0 s to 1.6 s at 10 MHz pulse clock rate
SEC, MS, US, NS
SDL
Opens the internal pulse
stepped delay mode
dwell-time-per-step
parameter.
100 microseconds to 10 s
SEC, MS, US
SDS
Opens the internal pulse
stepped delay mode delay1
start parameter.
0 ms to 167 ms at 100 MHz pulse clock rate;
0 ms to 419 ms at 40 MHz pulse clock rate;
0 s to 1.6 s at 10 MHz pulse clock rate
SEC, MS, US, NS
SDT
Opens the step sweep dwell
time parameter.
1 ms to 99 s
MS, SEC
SLDF
Opens the DF parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF0
Opens the F0 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF1
Opens the F1 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF2
Opens the F2 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF3
Opens the F3 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF4
Opens the F4 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF5
Opens the F5 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF6
Opens the F6 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
SLF7
Opens the F7 parameter of
the Secondary unit.
Frequency range of the Secondary MG369xC
model
GH, MH, KH, HZ
Table 2-2.
Parameter Entry Commands (3 of 5)
Mnemonic
Code
Parameter
Values
Units
Summary of Contents for MG369 C Series
Page 2: ......
Page 6: ...Contents 4 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 262: ...A 34 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 264: ...Index 2 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 265: ......