GP 500 - 1 : 

0 – 2500 Pa

GP 500 - 2 : 

0 – 10 000 Pa

Summary of Contents for GP 500 Series

Page 1: ...GP 500 1 0 2500 Pa GP 500 2 0 10 000 Pa...

Page 2: ......

Page 3: ...Define the number of external points 9 2 3 4 Perform an external generation 9 2 3 5 Delete the points 9 2 4 Configure the measurement programs 9 2 5 Launch a measurement program 10 2 6 Generate a pres...

Page 4: ......

Page 5: ...r interface 01 Screen 02 Param device configuration 03 Prog configuration of the pressure generation programs 04 Test tightness test 05 Unit units modification 06 Mode choice of Measurement or Generat...

Page 6: ...se and on the neutral Time delay 1 A 250 V Device must be connected to the protective ground 1 2 2 Technical specifications in measurement and pressure generation GP 500 0 2500 Pa Measuring range From...

Page 7: ...nual keypad Units Pa daPa hPa mmH2O mmHg mbar inWg All the accuracies indicated in this technical datasheet were stated in laboratory conditions and can be guaranteed for measurements carried out in t...

Page 8: ...rement in order to avoid the untimely variations and allow the exploitation of a more stable measurement Press on Param Go to the line Integration then press on OK With the arrows select the desired i...

Page 9: ...Measurement connections of the GP500 Also connect this calibration pressure bench to a standard device Go to the line External generation then press on OK Generate a setpoint with the calibration pres...

Page 10: ...Change step s then press on OK Go to Add then press on OK to add a stage to the program Enter the stage value with the numeric keypad then press on OK To delete a stage Go to the stage to delete with...

Page 11: ...Mode to be in Generation mode The green led located next to Generation lights up Enter the desired pressure with the numeric keypad then press on OK to validate The GP500 generates the desired pressur...

Page 12: ...ion then press on OK to adjust the duration during which the generator performs the test Adjust the duration with the numeric keypad then press on OK Once the adjustments are performed the GP500 must...

Page 13: ...OK Select with the arrows the desired intensity of the contrast between 0 and 3 Press on OK to validate 4 1 4 Set the key beep Go to the line Key sound then press on OK With the arrows select ON to a...

Page 14: ...formations then press on OK The screen displays the different information concerning the GP500 Software version Ex v1 000 b0274 Serial number Ex 5F 14 01 16777215 Calibration date Ex 19 06 2014 After...

Page 15: ...allation Insert the installation DVD in the DVD player of the computer The installation program starts automatically If not go to Workstation double click on the DVD player then on the LGP500 icon Fol...

Page 16: ...ave all the programs on the computer Click on to open a saved program in the computer In Steps part Click on the desired program The stages number corresponding to this program displays in the Steps p...

Page 17: ...n be corrected on the GP500 Click on the Correction tab The following window opens Click on Perform correction The following window opens Enter the correction date Enter the points number Click on Per...

Page 18: ...he untimely variations and allow the exploitation of a more stable measurement Click on Configuration tab The following window opens Enter the desired value of the integration of the pressure measurem...

Page 19: ...GP500 restarts and displays the message Programming flash during the updating At the end of the updating the GP500 turns off and the software indicates that the updating has succeeded Click on OK 5 8...

Page 20: ...NTang_GP500_03 12 14 RCS 24 P rigueux 349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice...