LV0
Description:
Turns off leveling of the output power.
This places the MG369xC in a fixed gain mode. In fixed gain mode, the ALC is disabled.
The RF level DAC and step attenuator (if installed) are used to control the relative power
level. Power is not detected at any point and the absolute output power level is
uncalibrated.
Functional
Category:
POWER LEVELING
Related
Commands:
DL1
,
IL1
,
LV1
,
PL1
Front Panel Key:
Level
| ALC Mode | Leveling > | Fixed Gain
LV1
Description:
Turns off leveling of the output power.
This places the MG369xC in auto fixed gain mode. In auto fixed gain mode, the
ALC RF Level DAC voltages are sampled with internal leveling enabled, then the ALC
is disabled and the RF Level DAC voltages are applied. Power is not detected again at
any point unless a frequency or power level parameter is adjusted.
Functional
Category:
POWER LEVELING
Related
Commands:
L1
,
IL1
,
LV0
,
PL1
Front Panel Key:
Level
|
ALC Mode
|
Leveling >
|
Auto Fixed Gain
LVP
Description:
Sets the instrument power level to 1 dB below peak leveled power.
Functional
Category:
POWER LEVELING
Front Panel Key:
In CW mode:
Level
|
Peak Lvld Pwr - 1dB
M0 <value> <unit>
Description:
Opens the M0 parameter.
Permits setting the M0 parameter. The frequency setting is determined by the frequency
range of the particular MG369xC model.
Functional
Category:
PARAMETER ENTRY
Output Command:
OM0
returns the M0 frequency value (in MHz) to the controller.
Value:
Frequency range of the MG369xC model
Units:
GH, MH, KH, HZ
Front Panel Key:
Frequency
| CW
|
Frequency Control >
|
Frequency List. . .
| highlight
M0
, then press
Edit Selected