Programming with GPIB Commands
2-24 Reset Programming and Default Conditions
MG369xC GPIB PM
PN: 10370-10374 Rev. F
2-63
2-24 Reset Programming and Default Conditions
describes the six methods that can be used to reset the signal generator. They provide a means for
quickly returning the MG369xC to its default (preprogrammed) operational state.
The default settings for the numeric frequency, sweep time, and power level parameters are the same as
those listed in Table 3-1 of the Series MG369xC Synthesized Signal Generator Operation Manual
(P/N: 10370-10373).
provides an example of a recommended sequence for programming a reset command. Using this
command sequence ensures that all parameters and commands assume their preprogrammed state each time
reset is desired.
Table 2-24.
Resetting the MG369xC GPIB Interface Circuits
Methods of Resetting GPIB Interface Circuits
Functions Affected
Default Conditions
1. Pressing the front panel menu RETURN TO
LOCAL soft key.
Bus Messages
Local
2. Pressing the front panel System menu RESET
soft key.
Service Request Modes
ES0, FB0, PE0, SB0, SE0,
SQ0, UL0, SB0, GTS, Local and
Local Lockout
3. Sending the RST command over the bus.
Same as 2 above
Same as 2 above except that the
local bus message is not reset.
4. Sending the MR command over the bus.
Same as 2 above
Same as 2 above.
5. Executing the interface message Device Clear. Same as 2 above.
Same as 2 above except that the
local bus message is not reset.
6. Turning power on and off.
Same as 2 above.
Places the GPIB into the
power-on state. Instrument state
does not change.
Sample Coding In Basic
10 CLEAR 705
20 OUTPUT 705; “FUL IL1 L1 10DM”
Explanation of Code:
Line 10 sends the Device Clear bus message. This message clears the signal generator GPIB interface.
Line 20 sends new front panel settings: Full Sweep, Internal Leveling, and Output Power Level of 10 dBm.
Figure 2-17.
Reset Programming Example
Summary of Contents for MG369 C Series
Page 2: ......
Page 6: ...Contents 4 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 262: ...A 34 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 264: ...Index 2 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 265: ......