A-4 Functional Listings
A-24
PN: 10370-10374 Rev. F
MG369xC GPIB PM
OFR
Returns the internal FM rate (in Hz) to the controller.
OFS
Returns the external FM sensitivity value (in MHz/V) to the controller.
OFW
Returns the name of the internal FM waveform to the controller.
OI
Returns the instrument identification string to the controller.
OL0
Returns the L0 power level value to the controller.
OL1
Returns the L1 power level value to the controller.
OL2
Returns the L2 power level value to the controller.
OL3
Returns the L3 power level value to the controller.
OL4
Returns the L4 power level value to the controller.
OL5
Returns the L5 power level value to the controller.
OL6
Returns the L6 power level value to the controller.
OL7
Returns the L7 power level value to the controller.
OL8
Returns the L8 power level value to the controller.
OL9
Returns the L9 power level value to the controller.
OLO
Returns the level offset power value to the controller.
OM0
Returns the M0 frequency value (in MHz) to the controller.
OM1
Returns the M1 frequency value (in MHz) to the controller.
OM2
Returns the M2 frequency value (in MHz) to the controller.
OM3
Returns the M3 frequency value (in MHz) to the controller.
OM4
Returns the M4 frequency value (in MHz) to the controller.
OM5
Returns the M5 frequency value (in MHz) to the controller.
OM6
Returns the M6 frequency value (in MHz) to the controller.
OM7
Returns the M7 frequency value (in MHz) to the controller.
OM8
Returns the M8 frequency value (in MHz) to the controller.
OM9
Returns the M9 frequency value (in MHz) to the controller.
OMD
Returns the name of the internal pulse mode to the controller.
OMM
1. Returns the AM depth measurement value (in %) to the controller.
2. Returns the FM deviation measurement value (in MHz) to the
controller.
OO
Returns the instrument option string to the controller.
OP5
Returns the internal or external pulse polarity (“HIGH”, “LOW”) to the
controller.
OPC
Returns the internal pulse clock rate (in MHz) to the controller.
OPD
Returns the power sweep dwell time (in ms) to the controller.
OPHD
Returns the internal
M deviation value (in radians) to the controller.
OPHM
Returns the name of the
M mode (“NARROW”, “WIDE”) to the
controller.
OPHR
Returns the internal
M rate (in Hz) to the controller.
OPHS
Returns the external
M sensitivity value (in radians/V) to the controller.
OPHW
Returns the name of the internal
M waveform to the controller.
Table A-13.
Output GPIB Command List (1 of 4)
Command Code
Function
Page