Command Directory
3-4 Commands
MG369xC GPIB PM
PN: 10370-10374 Rev. F
3-97
PW <value> <unit>
Description:
Opens the internal pulse width1 parameter (Same as W1).
Functional
Category:
PARAMETER ENTRY
Value:
30 ns to 167 ns at 100 MHz pulse clock rate;
25 ns to 419 ms at 40 MHz pulse clock rate;
100 ns to 1.6 s at 10 MHz pulse clock rate
Units:
SEC, MS, US, NS
Related
Commands:
W1
Front Panel Key:
Modulation
| Pulse
(internal)
| Wdth/Dly List. . . | Edit Selected
Example:
PMD1; PTG1; PW 50 US; IP
Turns internal pulse on with a single pulse, free run of width 50
s.
Output Command:
OPW
(in
s)
RC0
Description:
Selects RF to be off during frequency switching in CW, step sweep, and list sweep modes.
Functional
Category:
CONFIGURATION
Front Panel Key:
System
| Config | RF | DeltaF RF to Off
RC1
Description:
Selects RF to be on during frequency switching in CW, step sweep, and list sweep modes.
Functional
Category:
CONFIGURATION
Front Panel Key:
System
| Config | RF | DeltaF RF to On
RCF
Description:
Prepares the MG369xC to receive a new instrument setup recalled from the controller.
Functional
Category:
STORED SETUP
Related
Commands:
SAF
,
SAM
,
RCM
Front Panel Key:
N/A
RCM
Description:
Prepares the MG369xC to receive a new instrument setup and new stored setups recalled
from the controller.
Functional
Category:
STORED SETUP
Related
Commands:
SAF
,
SAM
,
RCF
Front Panel Key:
N/A
Summary of Contents for MG369 C Series
Page 2: ......
Page 6: ...Contents 4 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 262: ...A 34 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 264: ...Index 2 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 265: ......