background image

 

 

 

 

Operation and Maintenance Manual for 

IntelliHeat

™ Power Sources 

 

P/N 5050-0556 REV B 

 

This manual applies to: 

 

Model 

Part Number  

ST 30  

7008-0290-01 

ST 30E 

7008-0290-02 

ST 50 

7008-0291-01 

ST 50E 

7008-0291-02 

ST 65 

7008-0292-01 

ST 65E 

7008-0292-02 

ST 70 

7008-0293-01 

ST 70E 

7008-0293-02 

ST 75  

7008-0294-01 

ST 75E 

7008-0294-02 

ST 115 

7008-0295-01 

ST 115E 

7008-0295-02 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for IntelliHeat ST 115

Page 1: ...V B This manual applies to Model Part Number ST 30 7008 0290 01 ST 30E 7008 0290 02 ST 50 7008 0291 01 ST 50E 7008 0291 02 ST 65 7008 0292 01 ST 65E 7008 0292 02 ST 70 7008 0293 01 ST 70E 7008 0293 02 ST 75 7008 0294 01 ST 75E 7008 0294 02 ST 115 7008 0295 01 ST 115E 7008 0295 02 ...

Page 2: ...lled Power Supplies ST 30 ST 65 ST 75 Operation 10 Temperature Dial Lock 10 Analog Control LED Operation 10 Digital Temperature Controlled Power Supplies ST 50 ST 115 Operation 11 Digital Control LED Operation 11 LED Display 12 Temperature Setback Mode 12 Activating Setback Mode 12 Exiting Temperature Setback 12 Auto Off Mode 12 Exiting Auto Off 12 Customizing Your System 13 Introduction 13 Enteri...

Page 3: ...rce Requirements Domestic Models Export Models ST 30 ST 30E ST 50 ST 50E ST 65 ST 65E ST 70 ST 70E ST 75 ST 75E ST 115 Operates on 97 127 VAC 50 60Hz 80 Watts maximum at 115 VAC 60Hz ST 115E Operates on 197 253 VAC 50 60Hz 80 Watts maximum at 230 VAC 50Hz Shop Air Input Requirements ST 65 Only Pressure 5 48 Bar 80p si recommended Airflow 45 3 SLPM 1 6SCFM minimum Temperature Specifications All Mod...

Page 4: ... 2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 4 of 20 Power Supply Features A A B B C D E F C G J I H D E L E K C O P Q R O P Q R S O P Q R ST 30 ST 50 ST 65 FRONT BACK ...

Page 5: ... 2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 5 of 20 A B B M E N C L E K C D O P Q R ST 115 ST 75 R P T Q O ST 70 F C G J I H E L K R P T Q O ...

Page 6: ... menu functions I Digital control LED Indicates status of power supply J Digital display Displays temperature setting and menu functions K Vacuum inlet Vacuum connection for SX 90 TP 65 TP 100 Handpieces L Pressure control valve port Pressure airflow connection and control for TJ 85 handpiece M Power module LED Indicates status of power supply N Power module jack Allows user to increase or decreas...

Page 7: ...highly recommended to help protect personnel from solder flux fumes 5 Exercise proper precautions when using chemicals e g solder paste Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended by the manufacturer System Set Up Set up the Intelliheat system using the following steps 1 Store the shipping container in a convenient locat...

Page 8: ...upply Connection For ST 65 Only The ST 65 system utilizes an integral air venturi system to provide air pressure and vacuum for any connected PACE handpiece requiring air vacuum Your in house air supply must be connected to the system power source 1 Connect air supply to the ST 65 s air inlet on the back of the system 2 Install the Connector with Small Flexible Air Hose onto the Air Hose Fitting o...

Page 9: ...ed end of a male quick fit connector P N 1259 0087 into the free end of the 1 inch 2 5cm length of air hose connected to the FLOW OUT side of the VisiFilter 3 Connect the free end of the 137cm 54 inch length of air hose to the FLOW IN side of the VisiFilter 4 Insert the end of the quick fit connector on VisiFilter FLOW OUT side into the power source Vacuum Port 3 When using air pressure a connect ...

Page 10: ... Temp Locking Ring closest to the front panel Dial Control LED Operation The colored LED on the power source front panel indicates Power Receptacle output status LED Full On Red A fault has occurred Check or replace handpiece tip LED Full On Green Handpiece tip has reached set temperature LED Flashing Amber Unit is in setback Instant Set Back ISB cubby or the setback feature has been activated LED...

Page 11: ... offset may be entered if using massive tips To enter an offset simply press the program key while the system is in normal operation mode and enter the offset using the keypad The display will return to normal display mode in 5 7 seconds Digital Control LED Operation The colored LED on the power source front panel indicates calibration status LED Full On Red A fault has occurred Check handpiece an...

Page 12: ...p life and save energy the ST 50 and ST 115 systems can be programmed to automatically set back its Tip Temperature to 177 C 350 F after a selected period of handpiece inactivity adjustable 10 90 minutes in Set Up Mode As received from the factory this feature is enabled There are 2 ways to exit Temperature Setback Mode 1 Press and release Scroll up Key 2 Cycle the Power Switch Set Tip Temperature...

Page 13: ...and the system will return to normal operation If this occurs repeat steps 1 2 and enter the correct Password b The LED Display reads P Choose one of the following options i Press the Program Key to keep the currently stored Password including no Password ii To enter a password select a 3 digit number as the password using the keypad 1 to 999 Make a note of the entered Password Temperature Scale 4...

Page 14: ...f the following a Press and release the Program Key to keep the currently stored Auto Off time b Adjust the Auto Off value using the keypad c Press and release the Program Key to proceed to the next step Exiting Set Up Mode 9 The LED Display now reads End The Set Up Mode procedure is now complete Choose one of the following steps a Press and release the Scroll Up Key to exit Set Up Mode and return...

Page 15: ... the front of the unit 3 The LED indicator will turn amber while the tip is heating to the desired performance level 4 Once the tip has reached the desired heat level the LED indicator will turn green and the system is ready to use Auto Setback and Auto Off Features The ST 70 system comes standard with Auto Setback and Auto Off Features These are pre programmed for 30 minute Setback and 30 minute ...

Page 16: ...reen 5 260 ºC 500 F 1207 0446 02 P1 Turquoise 5 5 288 ºC 550 F 1207 0446 03 P1 Orange 6 316 ºC 600 F 1207 0446 04 P1 Gold 6 5 343 ºC 650 F 1207 0446 05 P1 Red 7 371 ºC 700 F 1207 0446 06 P1 Violet 7 5 399 ºC 750 F 1207 0446 07 P1 Black 8 427 ºC 800 F 1207 0446 08 P1 Silver 8 5 454 ºC 850 F Note Each ST 70 system includes 1 each 6 5 7 0 7 5 power modules ...

Page 17: ...ter setscrew on the Variable Temperature Control knob furthest from front panel using the Temp Locking Key hex key supplied with the system c Position the knob with the pointer aligned to match the temperature indicated on the temperature meter d Secure the knob in position by tightening the outer setscrew e Loosen the inner setscrew to unlock the Variable Temperature control if adjustment of oper...

Page 18: ...the correct password Open Sensor Error No handpiece is connected to the power receptacle Connect handpiece The handpiece heater assembly sensor is open Refer to the appropriate handpiece manual Shorted Sensor Error The handpiece heater assembly sensor is shorted Refer to the appropriate handpiece manual Over Circuit Error The handpiece heater assembly may be defective Refer to the appropriate hand...

Page 19: ...mp Time Lag 1159 0246 P5 1 Fuse 0 5 Amp Time Lag Export Models 1159 0213 P5 2 Silicone tubing For SX 90 TJ 85 Handpiece 1342 0015 08 3 Quick disconnect male fitting 1259 0087 P1 4 Venturi solenoid kit ST 65 Only 6993 0201 5 VisiFilter Sealed 1309 0020 P1 6 VisiFilter Replaceable 1309 0028 P1 7 Replaceable VisiFilter Elements Package of 101309 0027 P10 8 Replaceable VisiFilter Elements Package of 5...

Page 20: ...TY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user or provide parts without charge for installation by the user in the field at user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty se...

Reviews: