ComBi
line
05/04
51
The following points should be observed when wiring a new plug:
1.
The green/yellow-coloured wire ("EARTH") should be connected to the terminal which is either marked
with the letter "E", the "earth" symbol ( ), or coloured green or green/yellow.
2.
The blue-coloured wire ("NEUTRAL") should be connected to the terminal which is either marked with the
letter "N" or coloured black.
3.
The brown-coloured wire ("PHASE") should be connected to the terminal which is either marked with the
letter "L1, L2 and L3" or coloured red.
3.6
Connection on a counter
1.
Connect the machine at counter level and on a solid flat surface.
2.
Before the connections are made, check whether the main voltage corresponds to the voltage
indicated on the type plate.
3.
Determine the position of the machine on the counter.
4.
If necessary, make the transits on the counter for electricity, water and drainage, see fig. 3 for
measurements.
5.
Mount the supplied centering shoulders on the base plate.
6.
Connect the electricity supply, cold water supply and the overflow.
7.
Place the drip tray in front of the machine.
8.
Place the containers against the centring shoulders, place the coffee blenders into the containers
and put the filter units on the containers.
9.
Connect the container(s) by using the supplied short (60 cm) connection cable and put the mains
plug from the relevant column in the mains socket.
10.
Position the swivel arm over the centre of the filter.
The supplier cannot be held liable for any consequences arising
from failure during installation of the appliance according to the instructions.
Green/Yellow-
Earth
(E)
Blue
-
Neutral
(N)
Brown
-
Live
(L1)
Black
-
Live
(L2)
Black
-
Live
(L3)
Green/Yellow-
Earth
(E)
Brown
-
Live
(L1)
Black
-
Live
(L2)
Black
-
Live
(L3)
Green/Yellow-
Earth
(E)
Blue
-
Neutral
(N)
Brown
-
Live
(L)
fig. 3