05/04
ComBi
line
50
3.2
Preparation for positioning
•
Place the appliance at buffet height on a firm, level base that can withstand the weight of the
machine when filled.
•
Make sure that the appliance is level and placed somewhere where it will not cause damage
should leakage occur.
•
Place the appliance in such a way that the descaler filling opening on the top of the column can be reached.
•
The water supply line (G3/4" 15 mm pipe), a discharge for the overflow connection (25 mm hose) and
the power connection must be within half a meter of where the machine is positioned.
•
The user is responsible for ensuring that these technical installation preparations are executed according
to local regulations by qualified engineers.
•
The service engineer is only permitted to connect the appliance to the prepared connection points.
3.3
Water connection
Connect the appliance using the water hose to an easily accessible aeration tap that can be closed quickly
if problems arise. The minimum water pressure may not be under 0,2 Bar (at 5L/min. flow pressure)
3.3.1
Water treatment
You are emphatically advised to use a water softener and/or a water filter if the water contains too much chlorine
or is too hard (>8°dH). This enhances the quality of the drink and precludes having to descale the appliance too
often.
3.4
Water drainage
Connect the overflow connection to the open connection with a drain (syphon) in such a way that the excess
water can be drained in case of a malfunction or maintenance.
3.5
Electrical connection
The earthed wall socket and the fused group with a main switch belong to the electrical installation. No heavy
machines that could cause variations in power when being switched on, can be connected to this group.
A machine with power current (three phase) is delivered from the factory without plug. At delivery, the machine
must be provided with an electrically suitable plug as advised and provided by the installer.
•
(fig. 3) In case of 3N~ 400V (5-core cable).
•
(fig. 4) In case of 3~ 230V (4-core cable).
•
(fig. 5) In case of 1N~ 230V (3-core cable).
WARNING
•
Water always remains in the heating system: for this reason the
appliance must not be placed in an area where the temperature
can fall below freezing point.
WARNING
•
Supply voltages and frequencies can differ between countries. Check if the appliance
is suitable for connection to the local power mains. Check if the details on the type plate
correspond.
The appliance can only be connected to a cold water outlet.