05/04
ComBi
line
78
12.4.10
1
st
charge (menu 3.12)
The 1
st
charge volume can be increased if it is only found out
later in practise that the filtering process threatens to overflow
Setting the 1
st
charge volume
•
The 1
st
charge volume only becomes active if the
interval is set at 95% or less.
•
The 1
st
charge volume is set for half way through the
brewing process as standard.
•
The 1
st
charge volume can be set according to the
following overview (Table 7).
Set the desired 1
st
charge volume and confirm your changes
with the START button
or go back without making any
changes using the STOP button
.
12.4.11
Leak out time (menu 3.13)
The leak out time starts once the hot water distribution is
stopped. The leak out time through the filter can vary
depending on the type, size and/or amount of coffee.
Leak out time settings
•
If no leak out time is required the time can be set to 0.
There will then be no dripping symbol in the display
followed by a sound signal.
Set the required leak out time and confirm your changes with
the START button
or go back without saving any changes
by pressing the STOP button
.
1e charge volume (CB5W)
Fig. 31
Leak out time
Fig. 32
Table 7.
1
st
charge volume settings scope
CB 20
CB 10
CB 5
Model
10.000 ml
5.000 ml
2.500 ml
Standard
1
st
charge
8000 - 18.000 ml
5000 - 9000 ml
2500 - 4500 ml
Settings scope
250
250
250
Step
Tabel 8.
Leak out time
CB 20
CB 10
CB 5
Model
360 sec
300 sec
240 sec
Standard
leak out time
0 - 900
0 - 900
0 - 900
Settings scope
10
10
10