ANDREWS COMBIfl o
5
GB
CAUTION
If the water system is not in use for periods exceeding 14 days, there is an increased risk of
corrosion on all copper parts and an increase in bacterial growth. Follow the recognised measures
for Anti-legionella in section 5.4.2. to manage this risk
2.2 REGULATIONS AND STANDARDS
This heater must be installed in accordance with relevant Standard Specifi cations, Codes of Practice and cur-
rent Building Regulations, together with any special regional requirements of the Local Authorities, Gas under-
taking and Insurance Regulations for the Electrical Equipment of Buildings. The installation of this heater must
be in accordance with the relevant requirements of:
•
Health and safety at work act 1974
•
Building regulations 2010
•
Electricity at work regulations 1989
•
Management of health and safety at work regulations 1998
•
Manual handling regulations 1992
•
Model water byelaws 1986
•
BS 7671 - Requirements for electrical installations, IEE wiring, regulations
•
BS 6644 - Specifi cation for the installation of Gas fi red hot water boilers for rated inputs between 70kW
(net) and 1.8 MW
•
BS 7074-2 - Applications selection and Installation of expansion vessels and ancillary equipment for sealed
water systems.
•
BS 6880:1 Code of practice for low temperature hot water heating systems of output greater than 45kW.
•
BS 6880:2 Code of practice for low temperature hot water heating systems of output greater than 45kW.
•
BS 6880:3 Code of practice for low temperature hot water heating systems of output greater than 45kW.
•
CP 342:2 Code of practice for centralised hot water supply. Buildings other than individual dwellings.
•
IM/11 - Flues for commercial and Industrial Gas Fired Boilers and Air Heaters
•
IGE/UP/1 - Soundness Testing and Purging Procedure for Non Domestic Installations
•
IGE/UP/2 - Gas Installation Pipe work, Boosters and Compressors for Industrial and Commercial Premises
•
IGE/UP/10 - Installation of fl ued gas appliances in industrial and commercial premises.
•
IGE/UP/16 - Design for Natural Gas installations on industrial and commercial premises with respect to
hazardous area classifi cation and preparation of risk assessments
CAUTION
These manufacturer’s notes must not be taken in any way as over-riding statutory obligations.
Summary of Contents for COMBIflo 100/300
Page 9: ...ANDREWS COMBIflo 7 GB 3 1 GENERAL DIMENSIONS CONNECTIONS 3 0 TECHNICAL DATA ...
Page 12: ...ANDREWS COMBIflo 10 GB 3 4 APPLICATION EXAMPLES Single Heating Circuit Simple ...
Page 13: ...ANDREWS COMBIflo 11 GB Single Heating Circuit Immersion DHW Circulation pump ...
Page 16: ...ANDREWS COMBIflo 14 GB Heating Circuit External 0 10V control ...
Page 17: ...ANDREWS COMBIflo 15 GB BMS INTERNET CONNECTIONS ...
Page 18: ...ANDREWS COMBIflo 16 GB 3 5 WIRING DIAGRAMS PCB 1 ...
Page 19: ...ANDREWS COMBIflo 17 GB PCB 2 3 ...